<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="body"><title>Hauptteil</title><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Types</title></section><section id="sec_4"><label>4</label><title>Requirements</title><section id="sec_4.1"><label>4.1</label><title>Allowable limits of extractable substances from the gloves</title></section><section id="sec_4.2"><label>4.2</label><title>Heavy metals</title></section><section id="sec_4.3"><label>4.3</label><title>Phthalate content</title></section></section><section id="sec_5"><label>5</label><title>Sample preparation</title><section id="sec_5.1"><label>5.1</label><title>Determination of heavy metals</title></section><section id="sec_5.2"><label>5.2</label><title>Determination of potassium permanganate consumption and the evaporation residue</title></section><section id="sec_5.3"><label>5.3</label><title>Determination of the phthalate content</title></section></section><section id="sec_6"><label>6</label><title>Provision for use</title></section><section id="sec_7"><label>7</label><title>Labelling and marking</title></section></section><section id="sec_A"><label>Annex A</label><title>Determination of heavy metals (normative)</title><section id="sec_A.1"><label>A.1</label><title>Principle</title></section><section id="sec_A.2"><label>A.2</label><title>Apparatus</title></section><section id="sec_A.3"><label>A.3</label><title>Reagents</title></section><section id="sec_A.4"><label>A.4</label><title>Standard solutions</title></section><section id="sec_A.5"><label>A.5</label><title>Laboratory reagent blank</title></section><section id="sec_A.6"><label>A.6</label><title>Determination</title><section id="sec_A.6.1"><label>A.6.1</label><title>General</title><section id="sec_A.6.1.1"><label>A.6.1.1</label><title>Set up the instrument with proper operating parameters established from the manufacturer’s instruction manual. Allow the instrument to achieve thermal stability before beginning. Instructions provided by the manufacturer should be followed.</title></section><section id="sec_A.6.1.2"><label>A.6.1.2</label><title>Initiate the appropriate operating configuration of the computer.</title></section><section id="sec_A.6.1.3"><label>A.6.1.3</label><title>Profile and calibrate the instrument according to the manufacturer’s recommended procedures using the standard solutions (A.4).</title></section><section id="sec_A.6.1.4"><label>A.6.1.4</label><title>Begin the sample run by flushing the system with the reagent blank (A.5) between each sample.</title></section></section><section id="sec_A.6.2"><label>A.6.2</label><title>Recommended wavelengths and important spectral interferences</title></section><section id="sec_A.6.3"><label>A.6.3</label><title>Limit of detection</title><section id="sec_A.6.3.1"><label>A.6.3.1</label><title>The limit of detection, expressed as the concentration or the quantity, is derived from the smallest measure that can be detected with reasonable certainty for a given analytical procedure (IUPAC).</title></section><section id="sec_A.6.3.2"><label>A.6.3.2</label><title>The limit of detection (LOD) shall be calculated using Formula (A.1):</title></section><section id="sec_A.6.3.3"><label>A.6.3.3</label><title>Actual working detection limits are dependent on the type of instrumentation, detection device and sample introduction system used, and on the sample matrix. Therefore, these concentrations can vary between different instruments.</title></section></section></section><section id="sec_A.7"><label>A.7</label><title>Expression of results</title></section></section><section id="sec_B"><label>Annex B</label><title>Determination of potassium permanganate consumption (normative)</title><section id="sec_B.1"><label>B.1</label><title>Principle</title></section><section id="sec_B.2"><label>B.2</label><title>Apparatus</title></section><section id="sec_B.3"><label>B.3</label><title>Reagents</title></section><section id="sec_B.4"><label>B.4</label><title>Standard solutions</title></section><section id="sec_B.5"><label>B.5</label><title>Determination</title></section><section id="sec_B.6"><label>B.6</label><title>Expression of result</title></section></section><section id="sec_C"><label>Annex C</label><title>Determination of evaporated residue (normative)</title><section id="sec_C.1"><label>C.1</label><title>Principle</title></section><section id="sec_C.2"><label>C.2</label><title>Apparatus</title></section><section id="sec_C.3"><label>C.3</label><title> Reagents</title></section><section id="sec_C.4"><label>C.4</label><title>Determination</title></section><section id="sec_C.5"><label>C.5</label><title>Expression of result</title></section></section><section id="sec_D"><label>Annex D</label><title>Determination of phthalate content (normative)</title><section id="sec_D.1"><label>D.1</label><title>Principle</title></section><section id="sec_D.2"><label>D.2</label><title>Apparatus</title></section><section id="sec_D.3"><label>D.3</label><title>Reagents</title></section><section id="sec_D.4"><label>D.4</label><title>Standard solutions</title></section><section id="sec_D.5"><label>D.5</label><title>Determination</title><section id="sec_D.5.1"><label>D.5.1</label><title>Sampling, extraction, and gravimetric analysis for phthalate plasticisers</title><section id="sec_D.5.1.1"><label>D.5.1.1</label><title>Place the sample in a pre-weighed 150 ml flat bottom flask and heat in an oven at (105 ± 5) °C for (30 ± 5) min. Allow to cool in a desiccator.</title></section><section id="sec_D.5.1.2"><label>D.5.1.2</label><title>Weigh the flask and sample. Use a scalpel or other appropriate cutting utensil to cut a representative portion from the sample into small pieces, Φ &lt; 5 mm.</title></section><section id="sec_D.5.1.3"><label>D.5.1.3</label><title>Weigh accurately (2 ± 0,2) g of the pieces into a Soxhlet thimble and add cotton wool to the top of the thimble.</title></section><section id="sec_D.5.1.4"><label>D.5.1.4</label><title>Add approximately (50 ± 10) ml of diethyl ether into the flask. Reflux gently for 6 h ± 30 min. Allow sufficient time for the diethyl ether to cool.</title></section><section id="sec_D.5.1.5"><label>D.5.1.5</label><title>Evaporate the diethyl ether completely by mean of steam bath.</title></section><section id="sec_D.5.1.6"><label>D.5.1.6</label><title>Place the flask in an oven at (105 ± 5) °C for (30 ± 5) min. Allow to cool in a desiccator and weigh.</title></section><section id="sec_D.5.1.7"><label>D.5.1.7</label><title>Repeat the drying and cooling cycles until the difference between two consecutive weighings are not more than 0,0005 g. A blank solution shall be run consecutively.</title></section></section><section id="sec_D.5.2"><label>D.5.2</label><title>Preparation of sample extract solution for gas chromatography-mass spectrometry (GC-MS)</title><section id="sec_D.5.2.1"><label>D.5.2.1</label><title>To the weighed extract (D.5.1), add (50 ± 2) ml of n-hexane.</title></section><section id="sec_D.5.2.2"><label>D.5.2.2</label><title>Place a stopper to the flask and swirl to completely dissolve the extract.</title></section><section id="sec_D.5.2.3"><label>D.5.2.3</label><title>Decant the solution into a 200 ml volumetric flask, repeatedly rinsing the flask with n-hexane.</title></section><section id="sec_D.5.2.4"><label>D.5.2.4</label><title>Add n-hexane to the volumetric flask to bring the total volume to 200 ml.</title></section><section id="sec_D.5.2.5"><label>D.5.2.5</label><title>Prepare (if necessary) further diluted solutions using n-hexane such that the final concentration in solution is within the linear calibration concentration for phthalate present.</title></section><section id="sec_D.5.2.6"><label>D.5.2.6</label><title>Transfer a portion of the n-hexane solution into a capped vial for GC-MS analysis.</title></section><section id="sec_D.5.2.7"><label>D.5.2.7</label><title>The samples can be analysed for phthalate plasticisers by conditioning the GC-MS as follows.</title></section></section></section><section id="sec_D.6"><label>D.6</label><title>Expression of results</title></section></section><section id="sec_E"><label>Annex E</label><title>Precision (informative)</title><section id="sec_E.1"><label>E.1</label><title>General</title></section><section id="sec_E.2"><label>E.2</label><title>Details of test programmes</title></section><section id="sec_E.3"><label>E.3</label><title>Precision results</title></section></section><section id="sec_bibl"><title>Bibliography</title></section></toc>