<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Requirements</title><section id="sec_4.1"><label>4.1</label><title>Description</title></section><section id="sec_4.2"><label>4.2</label><title>Odour and taste</title></section><section id="sec_4.3"><label>4.3</label><title>Chemical requirements</title></section><section id="sec_4.4"><label>4.4</label><title>Hygienic requirements</title></section></section><section id="sec_5"><label>5</label><title>Test methods</title><section id="sec_5.1"><label>5.1</label><title>General</title></section><section id="sec_5.2"><label>5.2</label><title>Sample collection</title></section><section id="sec_5.3"><label>5.3</label><title>Test methods of chemical requirements</title></section></section><section id="sec_6"><label>6</label><title>Packaging, marking, storage and transportation</title><section id="sec_6.1"><label>6.1</label><title>Packaging</title></section><section id="sec_6.2"><label>6.2</label><title>Marking</title></section><section id="sec_6.3"><label>6.3</label><title>Storage and transportation</title></section></section><section id="sec_A"><label>Annex A</label><title>Determination of moisture content (normative)</title><section id="sec_A.1"><label>A.1</label><title>Vacuum drying oven method (Reference method)</title><section id="sec_A.1.1"><label>A.1.1</label><title>Apparatus</title></section><section id="sec_A.1.2"><label>A.1.2</label><title>Procedure</title></section><section id="sec_A.1.3"><label>A.1.3</label><title>Calculation</title></section><section id="sec_A.1.4"><label>A.1.4</label><title>Precision</title></section></section><section id="sec_A.2"><label>A.2</label><title>Karl Fisher</title><section id="sec_A.2.1"><label>A.2.1</label><title>Apparatus</title></section><section id="sec_A.2.2"><label>A.2.2</label><title>Procedure</title></section><section id="sec_A.2.3"><label>A.2.3</label><title>Precision</title></section></section><section id="sec_A.3"><label>A.3</label><title>Lyophilization</title><section id="sec_A.3.1"><label>A.3.1</label><title>Apparatus</title></section><section id="sec_A.3.2"><label>A.3.2</label><title>Procedure</title></section><section id="sec_A.3.3"><label>A.3.3</label><title>Calculation</title></section><section id="sec_A.3.4"><label>A.3.4</label><title>Precision</title></section></section></section><section id="sec_B"><label>Annex B</label><title>Determination of 10-HDA (normative)</title><section id="sec_B.1"><label>B.1</label><title>HPLC-UV External Standard (Reference method)</title><section id="sec_B.1.1"><label>B.1.1</label><title>Reagents</title></section><section id="sec_B.1.2"><label>B.1.2</label><title>Apparatus</title></section><section id="sec_B.1.3"><label>B.1.3</label><title>Procedure</title><section id="sec_B.1.3.1"><label>B.1.3.1</label><title>Sample treatment</title></section><section id="sec_B.1.3.2"><label>B.1.3.2</label><title>Chromatography conditions</title></section><section id="sec_B.1.3.3"><label>B.1.3.3</label><title>External calibration</title></section><section id="sec_B.1.3.4"><label>B.1.3.4</label><title>Sample determination</title></section></section><section id="sec_B.1.4"><label>B.1.4</label><title>Calculation</title></section><section id="sec_B.1.5"><label>B.1.5</label><title>Precision</title></section></section><section id="sec_B.2"><label>B.2</label><title>HPLC-UV internal standard (Alternative method)</title><section id="sec_B.2.1"><label>B.2.1</label><title>Reagents</title></section><section id="sec_B.2.2"><label>B.2.2</label><title>Apparatus</title></section><section id="sec_B.2.3"><label>B.2.3</label><title>Procedure</title><section id="sec_B.2.3.1"><label>B.2.3.1</label><title>Sample treatment</title></section><section id="sec_B.2.3.2"><label>B.2.3.2</label><title>Chromatography condition</title></section><section id="sec_B.2.3.3"><label>B.2.3.3</label><title>Determination of correction factor</title></section><section id="sec_B.2.3.4"><label>B.2.3.4</label><title>Sample determination</title></section></section><section id="sec_B.2.4"><label>B.2.4</label><title>Calculation</title></section><section id="sec_B.2.5"><label>B.2.5</label><title>Precision</title></section></section></section><section id="sec_C"><label>Annex C</label><title>Determination of protein (normative)</title><section id="sec_C.1"><label>C.1</label><title>Kjeldahl method (automatic) (Reference method)</title><section id="sec_C.1.1"><label>C.1.1</label><title>Reagents</title></section><section id="sec_C.1.2"><label>C.1.2</label><title>Apparatus</title></section><section id="sec_C.1.3"><label>C.1.3</label><title>Procedure</title><section id="sec_C.1.3.1"><label>C.1.3.1</label><title>Digestion</title></section><section id="sec_C.1.3.2"><label>C.1.3.2</label><title>Distillation</title></section><section id="sec_C.1.3.3"><label>C.1.3.3</label><title>Titration</title></section></section><section id="sec_C.1.4"><label>C.1.4</label><title>Calculation</title></section></section><section id="sec_C.2"><label>C.2</label><title>Kjheldal method (classical)</title><section id="sec_C.2.1"><label>C.2.1</label><title>Reagents</title></section><section id="sec_C.2.2"><label>C.2.2</label><title>Apparatus</title></section><section id="sec_C.2.3"><label>C.2.3</label><title>Procedure</title><section id="sec_C.2.3.1"><label>C.2.3.1</label><title>Cleaning of distillation unit</title></section><section id="sec_C.2.3.2"><label>C.2.3.2</label><title>Digestion</title></section><section id="sec_C.2.3.3"><label>C.2.3.3</label><title>Distillation</title></section><section id="sec_C.2.3.4"><label>C.2.3.4</label><title>Titration</title></section></section><section id="sec_C.2.4"><label>C.2.4</label><title>Calculation</title></section><section id="sec_C.2.5"><label>C.2.5</label><title>Precision</title></section></section><section id="sec_C.3"><label>C.3</label><title>Elemental analyser</title><section id="sec_C.3.1"><label>C.3.1</label><title>Apparatus</title></section><section id="sec_C.3.2"><label>C.3.2</label><title>Procedure for determination of the nitrogen content</title></section><section id="sec_C.3.3"><label>C.3.3</label><title>Calibration</title></section><section id="sec_C.3.4"><label>C.3.4</label><title>Precision</title></section><section id="sec_C.3.5"><label>C.3.5</label><title>Calculation</title></section></section></section><section id="sec_D"><label>Annex D</label><title>Determination of sugar (normative)</title><section id="sec_D.1"><label>D.1</label><title>Liquid chromatographic analysis (Reference method)</title><section id="sec_D.1.1"><label>D.1.1</label><title>Reagents</title></section><section id="sec_D.1.2"><label>D.1.2</label><title>Apparatus</title></section><section id="sec_D.1.3"><label>D.1.3</label><title>Procedure</title><section id="sec_D.1.3.1"><label>D.1.3.1</label><title>Sample treatment</title></section><section id="sec_D.1.3.2"><label>D.1.3.2</label><title>Chromatography conditions</title></section><section id="sec_D.1.3.3"><label>D.1.3.3</label><title>Calibration</title></section></section><section id="sec_D.1.4"><label>D.1.4</label><title>Calculation</title></section><section id="sec_D.1.5"><label>D.1.5</label><title>Precision</title></section></section><section id="sec_D.2"><label>D.2</label><title>Titration method</title><section id="sec_D.2.1"><label>D.2.1</label><title>Reagents</title></section><section id="sec_D.2.2"><label>D.2.2</label><title>Apparatus</title></section><section id="sec_D.2.3"><label>D.2.3</label><title>Procedure</title><section id="sec_D.2.3.1"><label>D.2.3.1</label><title>Sample treatment</title></section><section id="sec_D.2.3.2"><label>D.2.3.2</label><title>Sample solution titration</title></section></section><section id="sec_D.2.4"><label>D.2.4</label><title>Calculation</title></section><section id="sec_D.2.5"><label>D.2.5</label><title>Precision</title></section></section><section id="sec_D.3"><label>D.3</label><title>Gas chromatographic analysis</title><section id="sec_D.3.1"><label>D.3.1</label><title>Reagents</title></section><section id="sec_D.3.2"><label>D.3.2</label><title>Apparatus</title></section><section id="sec_D.3.3"><label>D.3.3</label><title>Procedure</title><section id="sec_D.3.3.1"><label>D.3.3.1</label><title>Sample treatment</title></section><section id="sec_D.3.3.2"><label>D.3.3.2</label><title>Chromatography conditions</title></section><section id="sec_D.3.3.3"><label>D.3.3.3</label><title>Sugar identification</title></section><section id="sec_D.3.3.4"><label>D.3.3.4</label><title>Sugar quantification - Determination of correction factor</title></section><section id="sec_D.3.3.5"><label>D.3.3.5</label><title>Calculation</title></section></section><section id="sec_D.3.4"><label>D.3.4</label><title>Precision</title></section></section></section><section id="sec_E"><label>Annex E</label><title>Determination of total acidity (normative)</title><section id="sec_E.1"><label>E.1</label><title>Reagents</title></section><section id="sec_E.2"><label>E.2</label><title>Apparatus</title></section><section id="sec_E.3"><label>E.3</label><title>Procedure</title></section><section id="sec_E.4"><label>E.4</label><title>Calculation</title></section><section id="sec_E.5"><label>E.5</label><title>Precision</title></section></section><section id="sec_F"><label>Annex F</label><title>Determination of total lipid (normative)</title><section id="sec_F.1"><label>F.1</label><title>Reagents</title></section><section id="sec_F.2"><label>F.2</label><title>Apparatus</title></section><section id="sec_F.3"><label>F.3</label><title>Procedure</title></section><section id="sec_F.4"><label>F.4</label><title>Calculation</title></section></section><section id="sec_G"><label>Annex G</label><title>Determination of C13 isotopic ratio (normative)</title><section id="sec_G.1"><label>G.1</label><title>General</title></section><section id="sec_G.2"><label>G.2</label><title>Procedure</title></section><section id="sec_G.3"><label>G.3</label><title>Calculation</title></section></section><section id="sec_H"><label>Annex H</label><title>Determination of furosine (informative)</title><section id="sec_H.1"><label>H.1</label><title>General</title></section><section id="sec_H.2"><label>H.2</label><title>Reagents</title></section><section id="sec_H.3"><label>H.3</label><title>Apparatus</title></section><section id="sec_H.4"><label>H.4</label><title>Chromatography conditions</title></section><section id="sec_H.5"><label>H.5</label><title>Procedure</title></section><section id="sec_H.6"><label>H.6</label><title>Calculation</title></section></section><section id="sec_I"><label>Annex I</label><title>Pollen screening (informative)</title><section id="sec_I.1"><label>I.1</label><title>Method including pollen acetolysis</title><section id="sec_I.1.1"><label>I.1.1</label><title>Samples preparation</title></section><section id="sec_I.1.2"><label>I.1.2</label><title>Procedure: acetolysis of pollens</title></section><section id="sec_I.1.3"><label>I.1.3</label><title>Identification and counting</title></section></section><section id="sec_I.2"><label>I.2</label><title>Method without pollen acetolysis</title><section id="sec_I.2.1"><label>I.2.1</label><title>References</title></section><section id="sec_I.2.2"><label>I.2.2</label><title>Sample preparation</title></section><section id="sec_I.2.3"><label>I.2.3</label><title>Identification and counting</title></section></section></section><section id="sec_bibl"><title>Bibliography</title></section></toc>