<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_intro"><title>Introduction</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Requirements</title><section id="sec_4.1"><label>4.1</label><title>General</title></section><section id="sec_4.2"><label>4.2</label><title>Field of view</title></section><section id="sec_4.3"><label>4.3</label><title>Requirements for welding filters</title><section id="sec_4.3.1"><label>4.3.1</label><title>Transmittance requirements and scale numbers</title><section id="sec_4.3.1.1"><label>4.3.1.1</label><title>General</title></section><section id="sec_4.3.1.2"><label>4.3.1.2</label><title>Transmittance requirements and scale numbers</title></section><section id="sec_4.3.1.3"><label>4.3.1.3</label><title>Marking of welding filters</title></section><section id="sec_4.3.1.4"><label>4.3.1.4</label><title>Additional requirements for peripheral awareness welding filters</title></section></section><section id="sec_4.3.2"><label>4.3.2</label><title>Narrow angle scatter (reduced luminance coefficient)</title></section><section id="sec_4.3.3"><label>4.3.3</label><title>Minimum robustness for unmounted welding filters (Static Load Test)</title></section><section id="sec_4.3.4"><label>4.3.4</label><title>Resistance to UV radiation</title></section></section><section id="sec_4.4"><label>4.4</label><title>Automatic welding filters</title><section id="sec_4.4.1"><label>4.4.1</label><title>General</title></section><section id="sec_4.4.2"><label>4.4.2</label><title>Transmittance requirements</title></section><section id="sec_4.4.3"><label>4.4.3</label><title>Luminous transmittance variation over time for automatic welding filters</title></section><section id="sec_4.4.4"><label>4.4.4</label><title>Variation in luminous transmittance for automatic welding filters</title><section id="sec_4.4.4.1"><label>4.4.4.1</label><title>General</title></section><section id="sec_4.4.4.2"><label>4.4.4.2</label><title>Uniformity of luminous transmittance and transmittance matching for flat automatic welding filters</title></section><section id="sec_4.4.4.3"><label>4.4.4.3</label><title>Angular dependence of luminous transmittance for flat automatic welding filters</title></section><section id="sec_4.4.4.4"><label>4.4.4.4</label><title>Combined uniformity and angular dependence of luminous transmittance for curved automatic welding filters</title></section></section><section id="sec_4.4.5"><label>4.4.5</label><title>Switching time and holding time of automatic welding filters</title></section><section id="sec_4.4.6"><label>4.4.6</label><title>Manual control of dark shade number</title></section><section id="sec_4.4.7"><label>4.4.7</label><title>Resistance to thermal exposure of automatic welding filters</title></section><section id="sec_4.4.8"><label>4.4.8</label><title>Optical sensitivity of welding arc detection by automatic welding filters (Optional requirement)</title></section><section id="sec_4.4.9"><label>4.4.9</label><title>Resistance to surface damage due to fine flying particles (Optional requirement)</title></section></section></section><section id="sec_5"><label>5</label><title>Requirements for welding helmets, welding hand shields, welding frames and welding mountings</title><section id="sec_5.1"><label>5.1</label><title>Optical requirements</title><section id="sec_5.1.1"><label>5.1.1</label><title>Non-filter area transmittance</title></section><section id="sec_5.1.2"><label>5.1.2</label><title>Luminous reflectance of welding helmets and welding hand shields</title></section></section><section id="sec_5.2"><label>5.2</label><title>Physical and mechanical requirements</title><section id="sec_5.2.1"><label>5.2.1</label><title>Area to be protected for welding helmets</title></section><section id="sec_5.2.2"><label>5.2.2</label><title>Light tightness of welding protectors</title></section><section id="sec_5.2.3"><label>5.2.3</label><title>Drop robustness for welding protectors</title></section><section id="sec_5.2.4"><label>5.2.4</label><title>Electrical insulation of welding helmets and welding hand shields</title></section><section id="sec_5.2.5"><label>5.2.5</label><title>Resistance to penetration by hot solids of welding helmets and welding hand shields</title></section><section id="sec_5.2.6"><label>5.2.6</label><title>Dimensions and mass of welding hand shields</title><section id="sec_5.2.6.1"><label>5.2.6.1</label><title>Minimum dimensions of welding hand shields</title></section><section id="sec_5.2.6.2"><label>5.2.6.2</label><title>Mass of welding hand shields</title></section></section></section></section><section id="sec_6"><label>6</label><title>Marking of welding protectors</title><section id="sec_6.1"><label>6.1</label><title>General</title></section><section id="sec_6.2"><label>6.2</label><title>Mandatory markings on welding filters</title></section><section id="sec_6.3"><label>6.3</label><title>Mandatory markings on welding protectors except for welding filters</title></section><section id="sec_6.4"><label>6.4</label><title>Optional markings on welding filters</title></section><section id="sec_6.5"><label>6.5</label><title>Optional markings on welding protectors except for welding filters</title></section><section id="sec_6.6"><label>6.6</label><title>Examples of markings</title></section></section><section id="sec_7"><label>7</label><title>Information to be supplied by the manufacturer</title></section><section id="sec_bibl"><title>Bibliography</title></section></toc>