<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_intro"><title>Introduction</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Principle</title></section><section id="sec_5"><label>5</label><title>Reagents</title></section><section id="sec_6"><label>6</label><title>Apparatus and equipment</title></section><section id="sec_7"><label>7</label><title>Preparation of standards solutions</title><section id="sec_7.1"><label>7.1</label><title>General</title></section><section id="sec_7.2"><label>7.2</label><title>Diluted nitric acid</title></section><section id="sec_7.3"><label>7.3</label><title>Diluting solution</title></section><section id="sec_7.4"><label>7.4</label><title>Internal standard solutions</title><section id="sec_7.4.1"><label>7.4.1</label><title>General</title></section><section id="sec_7.4.2"><label>7.4.2</label><title>Rhodium standard solution, 1 mg/l</title></section><section id="sec_7.4.3"><label>7.4.3</label><title>Lutetium standard solution, 1 mg/l</title></section></section><section id="sec_7.5"><label>7.5</label><title>Standard solutions</title><section id="sec_7.5.1"><label>7.5.1</label><title>General</title></section><section id="sec_7.5.2"><label>7.5.2</label><title>High concentration mixed standard solution, 10 mg/l</title></section><section id="sec_7.5.3"><label>7.5.3</label><title>Low concentration mixed standard solution, 0,1 mg/l</title></section></section><section id="sec_7.6"><label>7.6</label><title>Calibration blank solution</title></section><section id="sec_7.7"><label>7.7</label><title>Calibration solutions</title></section></section><section id="sec_8"><label>8</label><title>Procedure</title><section id="sec_8.1"><label>8.1</label><title>Preparation of samples</title></section><section id="sec_8.2"><label>8.2</label><title>Pressure assisted digestion</title><section id="sec_8.2.1"><label>8.2.1</label><title>General</title></section><section id="sec_8.2.2"><label>8.2.2</label><title>Preparation of sample by digestion — General case</title></section><section id="sec_8.2.3"><label>8.2.3</label><title>Preparation of sample by digestion — Specific cases</title></section><section id="sec_8.2.4"><label>8.2.4</label><title>Microwave digestion procedure</title></section><section id="sec_8.2.5"><label>8.2.5</label><title>Preparation of measurement solutions</title></section></section><section id="sec_8.3"><label>8.3</label><title>Inductively coupled plasma mass spectrometry</title><section id="sec_8.3.1"><label>8.3.1</label><title>ICP-MS operating conditions</title></section><section id="sec_8.3.2"><label>8.3.2</label><title>Quantification of the analytes by ICP-MS</title></section></section><section id="sec_8.4"><label>8.4</label><title>Quality control of the analysis</title><section id="sec_8.4.1"><label>8.4.1</label><title>General</title></section><section id="sec_8.4.2"><label>8.4.2</label><title>During digestion</title><section id="sec_8.4.2.1"><label>8.4.2.1</label><title>General case</title></section><section id="sec_8.4.2.2"><label>8.4.2.2</label><title>Suggested confirmatory test to check adsorption of antimony on vessels</title></section></section><section id="sec_8.4.3"><label>8.4.3</label><title>During analysis</title></section><section id="sec_8.4.4"><label>8.4.4</label><title>Example of ICP-MS sequence</title></section></section></section><section id="sec_9"><label>9</label><title>Calculation</title></section><section id="sec_10"><label>10</label><title>Method performance</title></section><section id="sec_11"><label>11</label><title>Test report</title></section><section id="sec_A"><label>Annex A</label><title>Performance of the method determined by the accuracy profile methodology (informative)</title></section><section id="sec_B"><label>Annex B</label><title>Evaluation of the method via ISO 5725 statistical approach (informative)</title></section><section id="sec_bibl"><title>Bibliography</title></section></toc>