<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_intro"><title>Introduction</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Symbols and abbreviated terms</title><section id="sec_4.1"><label>4.1</label><title>Symbols</title></section><section id="sec_4.2"><label>4.2</label><title>Abbreviated terms</title></section></section><section id="sec_5"><label>5</label><title>Conditions applicable to the test methods</title><section id="sec_5.1"><label>5.1</label><title>Number of interrogators to be tested</title></section><section id="sec_5.2"><label>5.2</label><title>Test environment</title></section><section id="sec_5.3"><label>5.3</label><title>RF environment</title></section><section id="sec_5.4"><label>5.4</label><title>Pre-conditioning</title></section><section id="sec_5.5"><label>5.5</label><title>Default tolerance</title></section><section id="sec_5.6"><label>5.6</label><title>Total measurement uncertainty</title></section><section id="sec_5.7"><label>5.7</label><title>Test result reporting</title></section><section id="sec_5.8"><label>5.8</label><title>Test communication parameters</title></section><section id="sec_5.9"><label>5.9</label><title>TE limits</title></section><section id="sec_5.10"><label>5.10</label><title>Human exposure to EMF</title></section></section><section id="sec_6"><label>6</label><title>Setup of TE for interrogator test</title><section id="sec_6.1"><label>6.1</label><title>Test apparatus and test circuits for ISO/IEC 18000-3 interrogators</title></section><section id="sec_6.2"><label>6.2</label><title>Test apparatus and test circuits for ISO/IEC 18000-61, ISO/IEC 18000-62, ISO/IEC 18000-63, ISO/IEC 18000-64 interrogators</title></section><section id="sec_6.3"><label>6.3</label><title>Test apparatus and test circuits for ISO/IEC 18000-7 interrogators</title></section></section><section id="sec_7"><label>7</label><title>Functional tests for inductive interrogators as defined in ISO/IEC 18000-2 and ISO/IEC 18000-3</title><section id="sec_7.1"><label>7.1</label><title>Interrogator sensitivity in Listen mode (Receiving mode)</title><section id="sec_7.1.1"><label>7.1.1</label><title>Purpose</title></section><section id="sec_7.1.2"><label>7.1.2</label><title>Test procedure</title></section><section id="sec_7.1.3"><label>7.1.3</label><title>Test report</title></section></section><section id="sec_7.2"><label>7.2</label><title>Interference rejection (I)</title><section id="sec_7.2.1"><label>7.2.1</label><title>Purpose</title></section><section id="sec_7.2.2"><label>7.2.2</label><title>Test procedure</title></section><section id="sec_7.2.3"><label>7.2.3</label><title>Test report</title></section></section><section id="sec_7.3"><label>7.3</label><title>Maximum EMF exposure (E)</title><section id="sec_7.3.1"><label>7.3.1</label><title>Purpose</title></section><section id="sec_7.3.2"><label>7.3.2</label><title>Test procedure</title></section><section id="sec_7.3.3"><label>7.3.3</label><title>Test report</title></section></section><section id="sec_7.4"><label>7.4</label><title>Ratio between field radiated and power consumption</title><section id="sec_7.4.1"><label>7.4.1</label><title>Purpose</title></section><section id="sec_7.4.2"><label>7.4.2</label><title>Test procedure</title></section><section id="sec_7.4.3"><label>7.4.3</label><title>Test report</title></section></section><section id="sec_7.5"><label>7.5</label><title>Field strength distribution</title><section id="sec_7.5.1"><label>7.5.1</label><title>Purpose</title></section><section id="sec_7.5.2"><label>7.5.2</label><title>Test procedure</title></section><section id="sec_7.5.3"><label>7.5.3</label><title>Test report</title></section></section></section><section id="sec_8"><label>8</label><title>Functional tests for interrogators as defined in ISO/IEC 18000-6 and in particular ISO/IEC 18000-63</title><section id="sec_8.1"><label>8.1</label><title>Receiver sensitivity for UHF interrogators using wave propagation</title><section id="sec_8.1.1"><label>8.1.1</label><title>Purpose</title></section><section id="sec_8.1.2"><label>8.1.2</label><title>Test procedure</title></section><section id="sec_8.1.3"><label>8.1.3</label><title>Test report</title></section></section><section id="sec_8.2"><label>8.2</label><title>Inductive UHF interrogators</title></section></section><section id="sec_9"><label>9</label><title>Functional tests for 433,920 MHz propagative interrogators as defined in ISO/IEC 18000-7</title><section id="sec_9.1"><label>9.1</label><title>Identification electromagnetic field threshold (E) and frequency tolerance</title><section id="sec_9.1.1"><label>9.1.1</label><title>Purpose</title></section><section id="sec_9.1.2"><label>9.1.2</label><title>Test procedure</title></section><section id="sec_9.1.3"><label>9.1.3</label><title>Test report</title></section></section><section id="sec_9.2"><label>9.2</label><title>Reading/writing electromagnetic field threshold (E) and frequency tolerance</title><section id="sec_9.2.1"><label>9.2.1</label><title>Purpose</title></section><section id="sec_9.2.2"><label>9.2.2</label><title>Test procedure</title></section><section id="sec_9.2.3"><label>9.2.3</label><title>Test report</title></section></section><section id="sec_9.3"><label>9.3</label><title>Sensitivity directivity (S)</title><section id="sec_9.3.1"><label>9.3.1</label><title>Purpose</title></section><section id="sec_9.3.2"><label>9.3.2</label><title>Test procedure</title></section><section id="sec_9.3.3"><label>9.3.3</label><title>Test report</title></section></section><section id="sec_9.4"><label>9.4</label><title>Interference rejection (I)</title><section id="sec_9.4.1"><label>9.4.1</label><title>Purpose</title></section><section id="sec_9.4.2"><label>9.4.2</label><title>Test procedure</title></section><section id="sec_9.4.3"><label>9.4.3</label><title>Test report</title></section></section><section id="sec_9.5"><label>9.5</label><title>Maximum operating electromagnetic field (E)</title><section id="sec_9.5.1"><label>9.5.1</label><title>Purpose</title></section><section id="sec_9.5.2"><label>9.5.2</label><title>Test procedure</title></section><section id="sec_9.5.3"><label>9.5.3</label><title>Test report</title></section></section><section id="sec_9.6"><label>9.6</label><title>Survival electromagnetic field (E)</title><section id="sec_9.6.1"><label>9.6.1</label><title>Purpose</title></section><section id="sec_9.6.2"><label>9.6.2</label><title>Test procedure</title></section><section id="sec_9.6.3"><label>9.6.3</label><title>Test report</title></section></section></section><section id="sec_A"><label>Annexe A</label><title>Backscatter power measurement (normative)</title></section><section id="sec_bibl"><title>Bibliography</title></section></toc>