<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_intro"><title>Introduction</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Principle</title></section><section id="sec_5"><label>5</label><title>Equipment and materials</title></section><section id="sec_6"><label>6</label><title>Test procedures</title><section id="sec_6.1"><label>6.1</label><title>Welding procedure selection</title></section><section id="sec_6.2"><label>6.2</label><title>Manual metal arc welding</title><section id="sec_6.2.1"><label>6.2.1</label><title>Setting up the test chamber</title></section><section id="sec_6.2.2"><label>6.2.2</label><title>Trial tests</title><section id="sec_6.2.2.1"><label>6.2.2.1</label><title>Trial test to set the test current</title></section><section id="sec_6.2.2.2"><label>6.2.2.2</label><title>Trial test to establish the test time for emission rate tests</title></section></section><section id="sec_6.2.3"><label>6.2.3</label><title>Emission rate tests</title></section><section id="sec_6.2.4"><label>6.2.4</label><title>Fume collection for analysis</title></section></section><section id="sec_6.3"><label>6.3</label><title>Continuous wire processes</title><section id="sec_6.3.1"><label>6.3.1</label><title>Setting up of the test equipment</title></section><section id="sec_6.3.2"><label>6.3.2</label><title>Trial tests</title><section id="sec_6.3.2.1"><label>6.3.2.1</label><title>Trial test to set the test conditions</title></section><section id="sec_6.3.2.2"><label>6.3.2.2</label><title>Trial test to establish the test time for emission rate tests</title></section></section><section id="sec_6.3.3"><label>6.3.3</label><title>Emission rate tests</title></section><section id="sec_6.3.4"><label>6.3.4</label><title>Fume collection for analysis</title></section></section><section id="sec_6.4"><label>6.4</label><title>Analysis of the fume collected</title></section></section><section id="sec_7"><label>7</label><title>Calculating and reporting the results</title></section><section id="sec_A"><label>Annex A</label><title>Possible designs of test chamber (informative)</title><section id="sec_A.1"><label>A.1</label><title>Test chambers of the “hood” type</title><section id="sec_A.1.1"><label>A.1.1</label><title>Field of use</title></section><section id="sec_A.1.2"><label>A.1.2</label><title>Design 1</title></section><section id="sec_A.1.3"><label>A.1.3</label><title>Design 2</title></section></section><section id="sec_A.2"><label>A.2</label><title>Test chambers of the “fume box” type</title><section id="sec_A.2.1"><label>A.2.1</label><title>Field of use</title></section><section id="sec_A.2.2"><label>A.2.2</label><title>Design 3</title></section></section><section id="sec_A.3"><label>A.3</label><title>Interconvertible test chambers</title><section id="sec_A.3.1"><label>A.3.1</label><title>Field of use</title></section><section id="sec_A.3.2"><label>A.3.2</label><title>Design 4</title></section></section></section><section id="sec_B"><label>Annex B</label><title>Equipment notes (informative)</title><section id="sec_B.1"><label>B.1</label><title>Construction of the test chamber</title></section><section id="sec_B.2"><label>B.2</label><title>Filters</title></section><section id="sec_B.3"><label>B.3</label><title>Extraction unit</title></section><section id="sec_B.4"><label>B.4</label><title>Equipment for measuring shielding gas flow rate</title></section><section id="sec_B.5"><label>B.5</label><title>Test pieces</title></section><section id="sec_B.6"><label>B.6</label><title>Interference-free environment</title></section></section><section id="sec_C"><label>Annex C</label><title>Welding parameters (informative)</title><section id="sec_C.1"><label>C.1</label><title>Starting test conditions</title></section><section id="sec_C.2"><label>C.2</label><title>Welding position</title></section><section id="sec_C.3"><label>C.3</label><title>Torch angle and travel direction</title></section><section id="sec_C.4"><label>C.4</label><title>Welding speed</title></section><section id="sec_C.5"><label>C.5</label><title>Polarity</title></section><section id="sec_C.6"><label>C.6</label><title>The CTWD</title></section><section id="sec_C.7"><label>C.7</label><title>Shielding gas flow rate</title></section><section id="sec_C.8"><label>C.8</label><title>Gas nozzle</title></section></section><section id="sec_D"><label>Annex D</label><title>Test procedures (normative)</title><section id="sec_D.1"><label>D.1</label><title>Attaching the leads for measuring voltage and current</title></section><section id="sec_D.2"><label>D.2</label><title>Setting the CTWD</title></section></section><section id="sec_E"><label>Annex E</label><title>Test report (normative)</title></section><section id="sec_bibl"><title>Bibliography</title></section></toc>