<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_intro"><title>Introduction</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Symbols and abbreviated terms</title></section><section id="sec_5"><label>5</label><title>Principle</title></section><section id="sec_6"><label>6</label><title>Description of the automated measuring systems</title><section id="sec_6.1"><label>6.1</label><title>Sampling and sample gas conditioning systems</title></section><section id="sec_6.2"><label>6.2</label><title>Analyser equipment</title></section></section><section id="sec_7"><label>7</label><title>Performance characteristics and criteria</title><section id="sec_7.1"><label>7.1</label><title>Performance criteria</title></section><section id="sec_7.2"><label>7.2</label><title>Determination of the performance characteristics</title><section id="sec_7.2.1"><label>7.2.1</label><title>Performance test</title></section><section id="sec_7.2.2"><label>7.2.2</label><title>Ongoing quality control</title></section></section></section><section id="sec_8"><label>8</label><title>Selection and installation procedure</title><section id="sec_8.1"><label>8.1</label><title>Choice of the measuring system</title></section><section id="sec_8.2"><label>8.2</label><title>Sampling</title><section id="sec_8.2.1"><label>8.2.1</label><title>Sampling location</title></section><section id="sec_8.2.2"><label>8.2.2</label><title>Representative sampling</title></section></section><section id="sec_8.3"><label>8.3</label><title>Calculation</title><section id="sec_8.3.1"><label>8.3.1</label><title>Conversion from volume to mass concentration for CO</title></section><section id="sec_8.3.2"><label>8.3.2</label><title>Conversion from wet to dry conditions for CO, CO and O concentrations</title></section></section></section><section id="sec_9"><label>9</label><title>Quality assurance and quality control procedures</title><section id="sec_9.1"><label>9.1</label><title>General</title></section><section id="sec_9.2"><label>9.2</label><title>Frequency of checks</title></section><section id="sec_9.3"><label>9.3</label><title>Calibration, validation and measurement uncertainty</title></section></section><section id="sec_10"><label>10</label><title>Test report</title></section><section id="sec_A"><label>Annex A</label><title>Infrared absorption method (CO and CO) (informative)</title><section id="sec_A.1"><label>A.1</label><title>Measuring principle based on infrared absorption technique</title></section><section id="sec_A.2"><label>A.2</label><title>Description of the automated measuring system</title><section id="sec_A.2.1"><label>A.2.1</label><title>Cold-dry extractive system</title></section><section id="sec_A.2.2"><label>A.2.2</label><title>Hot-wet extractive system</title></section></section><section id="sec_A.3"><label>A.3</label><title>Components of the sampling and the sample gas conditioning systems</title><section id="sec_A.3.1"><label>A.3.1</label><title>Sampling probe</title></section><section id="sec_A.3.2"><label>A.3.2</label><title>Filter</title></section><section id="sec_A.3.3"><label>A.3.3</label><title>Sampling line</title></section><section id="sec_A.3.4"><label>A.3.4</label><title>Moisture removal system</title></section><section id="sec_A.3.5"><label>A.3.5</label><title>Sampling pump</title></section><section id="sec_A.3.6"><label>A.3.6</label><title>Secondary filter</title></section><section id="sec_A.3.7"><label>A.3.7</label><title>Flow controller and flow meter</title></section></section></section><section id="sec_B"><label>Annex B</label><title>Extractive O measurement techniques (informative)</title><section id="sec_B.1"><label>B.1</label><title>Measuring principle based on the paramagnetic, zirconium oxide and electrochemical cell methods</title><section id="sec_B.1.1"><label>B.1.1</label><title>Paramagnetic method (O)</title></section><section id="sec_B.1.2"><label>B.1.2</label><title>Zirconium oxide method (O)</title></section><section id="sec_B.1.3"><label>B.1.3</label><title>Extractive electrochemical cell method (O)</title></section></section><section id="sec_B.2"><label>B.2</label><title>Description of the automated measuring system</title></section></section><section id="sec_C"><label>Annex C</label><title>In situ CO, CO and O measurement (informative)</title><section id="sec_C.1"><label>C.1</label><title>Measuring principle based on in situ CO, CO and O measurement with Tuneable Laser Spectroscopy (TLS) technique</title></section><section id="sec_C.2"><label>C.2</label><title>In situ cross duct measuring systems</title><section id="sec_C.2.1"><label>C.2.1</label><title>General</title></section><section id="sec_C.2.2"><label>C.2.2</label><title>Components of an in situ TLS measuring system (cross duct)</title><section id="sec_C.2.2.1"><label>C.2.2.1</label><title>Transmitter and receiver unit</title></section><section id="sec_C.2.2.2"><label>C.2.2.2</label><title>Optical window purge</title></section><section id="sec_C.2.2.3"><label>C.2.2.3</label><title>Validation cell [CO only]</title></section><section id="sec_C.2.2.4"><label>C.2.2.4</label><title>Pressure and temperature sensor</title></section></section></section><section id="sec_C.3"><label>C.3</label><title>In situ point measuring systems</title><section id="sec_C.3.1"><label>C.3.1</label><title>General</title></section><section id="sec_C.3.2"><label>C.3.2</label><title>Components of an in situ TLS measuring system (point monitor)</title><section id="sec_C.3.2.1"><label>C.3.2.1</label><title>General</title></section><section id="sec_C.3.2.2"><label>C.3.2.2</label><title>Instrument transceiver</title></section><section id="sec_C.3.2.3"><label>C.3.2.3</label><title>Measurement cell</title></section><section id="sec_C.3.2.4"><label>C.3.2.4</label><title>Probe filter</title></section></section></section></section><section id="sec_D"><label>Annex D</label><title>Operational gases (normative)</title><section id="sec_D.1"><label>D.1</label><title>General</title></section><section id="sec_D.2"><label>D.2</label><title>Zero gas</title></section><section id="sec_D.3"><label>D.3</label><title>Span gases</title></section><section id="sec_D.4"><label>D.4</label><title>Reference gas</title></section></section><section id="sec_E"><label>Annex E</label><title>Procedures for determination of the performance characteristics (normative)</title><section id="sec_E.1"><label>E.1</label><title>General</title></section><section id="sec_E.2"><label>E.2</label><title>Response time</title></section><section id="sec_E.3"><label>E.3</label><title>Repeatability at zero and at span level</title><section id="sec_E.3.1"><label>E.3.1</label><title>General</title></section><section id="sec_E.3.2"><label>E.3.2</label><title>Standard deviation of repeatability in laboratory at zero point</title></section><section id="sec_E.3.3"><label>E.3.3</label><title>Standard deviation of repeatability in laboratory at span point</title></section></section><section id="sec_E.4"><label>E.4</label><title>Lack-of-fit (Linearity)</title></section><section id="sec_E.5"><label>E.5</label><title>Cross-sensitivity</title></section><section id="sec_E.6"><label>E.6</label><title>Check of losses in the sampling line and conditioning system</title></section><section id="sec_E.7"><label>E.7</label><title>Check of leakage in the sampling line and conditioning system</title></section><section id="sec_E.8"><label>E.8</label><title>Zero drift and span drift for performance test</title></section><section id="sec_E.9"><label>E.9</label><title>Zero drift and span drift for periodical test</title></section><section id="sec_E.10"><label>E.10</label><title>Excursion of measurement beam of cross-stack in situ AMS</title></section><section id="sec_E.11"><label>E.11</label><title>Sensitivity to sample gas pressure, for a pressure change of 2 kPa</title></section><section id="sec_E.12"><label>E.12</label><title>Influence of the sample gas flow for extractive AMS</title></section><section id="sec_E.13"><label>E.13</label><title>Sensitivity to ambient temperature, for a change of 10 K in the temperature range specified by the manufacturer</title></section><section id="sec_E.14"><label>E.14</label><title>Sensitivity to electric voltage</title></section></section><section id="sec_F"><label>Annex F</label><title>Examples of the results for the assessment of CO, CO and O AMS (informative)</title><section id="sec_F.1"><label>F.1</label><title>CO measurement</title></section><section id="sec_F.2"><label>F.2</label><title>CO measurement</title></section><section id="sec_F.3"><label>F.3</label><title>O measurement</title></section></section><section id="sec_G"><label>Annex G</label><title>Calculation of uncertainty of measurement of CO, CO and O (informative)</title><section id="sec_G.1"><label>G.1</label><title>General</title></section><section id="sec_G.2"><label>G.2</label><title>Results of uncertainty calculation</title></section><section id="sec_G.3"><label>G.3</label><title>NDIR dual-beam type AMS</title></section><section id="sec_G.4"><label>G.4</label><title>In situ TLS type AMS</title></section><section id="sec_G.5"><label>G.5</label><title>NDIR cross modulation type AMS</title></section><section id="sec_G.6"><label>G.6</label><title>NDIR dual-beam type AMS</title></section><section id="sec_G.7"><label>G.7</label><title>In situ TLS type AMS</title></section><section id="sec_G.8"><label>G.8</label><title>Magneto pneumatic type AMS</title></section><section id="sec_G.9"><label>G.9</label><title>Dumb-bell type AMS</title></section><section id="sec_G.10"><label>G.10</label><title>Electrochemical cell AMS</title></section><section id="sec_G.11"><label>G.11</label><title>Extractive ZrO type AMS</title></section><section id="sec_G.12"><label>G.12</label><title>In situ hot ZrOtype AMS</title></section><section id="sec_G.13"><label>G.13</label><title>In situ TLS type AMS</title></section></section><section id="sec_bibl"><title>Bibliography</title></section></toc>