<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Principle</title></section><section id="sec_5"><label>5</label><title>Reagents</title><section id="sec_5.1"><label>5.1</label><title>General</title></section><section id="sec_5.2"><label>5.2</label><title>Hydrochloric acid solution, 1+1</title></section><section id="sec_5.3"><label>5.3</label><title>Nitric acid solution, 1+1</title></section><section id="sec_5.4"><label>5.4</label><title>Hydrofluoric acid solution, 1+1</title></section><section id="sec_5.5"><label>5.5</label><title>Titanium</title></section><section id="sec_5.6"><label>5.6</label><title>Indium solution, 1 g/l</title></section><section id="sec_5.7"><label>5.7</label><title>Cobalt solution, 1 g/l</title></section><section id="sec_5.8"><label>5.8</label><title>Strontium solution, 1 g/l</title></section><section id="sec_5.9"><label>5.9</label><title>Aluminium standard solution, 1 g/l</title></section><section id="sec_5.10"><label>5.10</label><title>Vanadium standard solution, 1 g/l</title></section></section><section id="sec_6"><label>6</label><title>Apparatus</title><section id="sec_6.1"><label>6.1</label><title>General</title></section><section id="sec_6.2"><label>6.2</label><title>Volumetric glassware</title></section><section id="sec_6.3"><label>6.3</label><title>Plastic beaker, volumetric plastic flask and plastic watch glass</title></section><section id="sec_6.4"><label>6.4</label><title>Atomic emission spectrometer, equipped with an inductively coupled plasma (ICP-AES)</title></section></section><section id="sec_7"><label>7</label><title>Sampling</title></section><section id="sec_8"><label>8</label><title>Procedure</title><section id="sec_8.1"><label>8.1</label><title>Test portion</title></section><section id="sec_8.2"><label>8.2</label><title>Number of determinations</title></section><section id="sec_8.3"><label>8.3</label><title>Preparation of the calibration solutions</title></section><section id="sec_8.4"><label>8.4</label><title>Preparation of the test solutions</title></section><section id="sec_8.5"><label>8.5</label><title>Determination</title><section id="sec_8.5.1"><label>8.5.1</label><title>General</title></section><section id="sec_8.5.2"><label>8.5.2</label><title>Spectrometric measurements of the calibration solutions</title></section><section id="sec_8.5.3"><label>8.5.3</label><title>Spectrometric measurements of the test solutions</title></section></section></section><section id="sec_9"><label>9</label><title>Expression of result</title></section><section id="sec_10"><label>10</label><title>Precision</title></section><section id="sec_11"><label>11</label><title>Test report</title></section><section id="sec_A"><label>Annex A</label><title>Additional information on the international inter-laboratory test (informative)</title></section><section id="sec_B"><label>Annex B</label><title>Graphical representation of the precision data (informative)</title></section><section id="sec_bibl"><title>Bibliography</title></section></toc>