<?xml version="1.0" encoding="UTF-8"?><toc><section id="sec_foreword"><title>Foreword</title></section><section id="sec_1"><label>1</label><title>Scope</title></section><section id="sec_2"><label>2</label><title>Normative references</title></section><section id="sec_3"><label>3</label><title>Terms and definitions</title></section><section id="sec_4"><label>4</label><title>Symbols and units</title></section><section id="sec_5"><label>5</label><title>Performance warranty</title><section id="sec_5.1"><label>5.1</label><title>General</title></section><section id="sec_5.2"><label>5.2</label><title>Subject of technical warranties</title><section id="sec_5.2.1"><label>5.2.1</label><title>General</title></section><section id="sec_5.2.2"><label>5.2.2</label><title>Refrigerating capacity</title></section><section id="sec_5.2.3"><label>5.2.3</label><title>Compressor absorbed power</title></section><section id="sec_5.2.4"><label>5.2.4</label><title>Absorbed power of ancillaries</title></section><section id="sec_5.2.5"><label>5.2.5</label><title>Absorbed power of the entire system</title></section><section id="sec_5.2.6"><label>5.2.6</label><title>Cooling water demand</title></section><section id="sec_5.2.7"><label>5.2.7</label><title>Coefficient of performance</title></section></section><section id="sec_5.3"><label>5.3</label><title>Operating conditions for technical warranties</title><section id="sec_5.3.1"><label>5.3.1</label><title>General</title></section><section id="sec_5.3.2"><label>5.3.2</label><title>Overall refrigerating capacity</title></section><section id="sec_5.3.3"><label>5.3.3</label><title>Net or useful refrigerating capacity</title></section><section id="sec_5.3.4"><label>5.3.4</label><title>Conversion to warranty conditions</title></section></section><section id="sec_5.4"><label>5.4</label><title>Tolerance</title></section><section id="sec_5.5"><label>5.5</label><title>Acceptance limit</title></section></section><section id="sec_6"><label>6</label><title>Test preparation and procedure</title></section><section id="sec_7"><label>7</label><title>Measuring instruments</title><section id="sec_7.1"><label>7.1</label><title>General</title></section><section id="sec_7.2"><label>7.2</label><title>Temperature measuring instruments</title></section><section id="sec_7.3"><label>7.3</label><title>Pressure gauges</title></section><section id="sec_7.4"><label>7.4</label><title>Measuring instruments for electric power</title></section><section id="sec_7.5"><label>7.5</label><title>Flow meters</title></section><section id="sec_7.6"><label>7.6</label><title>Speed measuring devices</title></section><section id="sec_7.7"><label>7.7</label><title>Torque measuring devices</title></section><section id="sec_7.8"><label>7.8</label><title>Time measuring devices</title></section><section id="sec_7.9"><label>7.9</label><title>Mass measuring devices</title></section></section><section id="sec_8"><label>8</label><title>Determination of the refrigerating capacity</title><section id="sec_8.1"><label>8.1</label><title>Direct methods</title><section id="sec_8.1.1"><label>8.1.1</label><title>Overall refrigerating capacity</title><section id="sec_8.1.1.1"><label>8.1.1.1</label><title>General</title></section><section id="sec_8.1.1.2"><label>8.1.1.2</label><title>Determination of the refrigerant mass flow from the heat balance</title></section><section id="sec_8.1.1.3"><label>8.1.1.3</label><title>Determination of the refrigerant mass flow by means of a flow meter</title></section></section><section id="sec_8.1.2"><label>8.1.2</label><title>Net refrigerating capacity for a liquid cooled medium</title></section><section id="sec_8.1.3"><label>8.1.3</label><title>Useful refrigerating capacity</title><section id="sec_8.1.3.1"><label>8.1.3.1</label><title>General</title></section><section id="sec_8.1.3.2"><label>8.1.3.2</label><title>Direct measurement</title></section><section id="sec_8.1.3.3"><label>8.1.3.3</label><title>Calorimetric measurement</title></section></section></section><section id="sec_8.2"><label>8.2</label><title>Indirect methods</title><section id="sec_8.2.1"><label>8.2.1</label><title>General</title></section><section id="sec_8.2.2"><label>8.2.2</label><title>Determination of the overall refrigerating capacity by means of a calibrated compressor</title></section><section id="sec_8.2.3"><label>8.2.3</label><title>Determination of the net refrigerating capacity</title></section><section id="sec_8.2.4"><label>8.2.4</label><title>Determination of the useful refrigerating capacity</title></section><section id="sec_8.2.5"><label>8.2.5</label><title>Determination of the overall refrigerating capacity from the overall energy balance</title></section></section></section><section id="sec_9"><label>9</label><title>Determination of the drive power</title><section id="sec_9.1"><label>9.1</label><title>Power absorbed by the compressor</title></section></section><section id="sec_10"><label>10</label><title>Measurement uncertainties</title></section><section id="sec_11"><label>11</label><title>Results, conversion to guaranteed values</title></section><section id="sec_12"><label>12</label><title>Material properties</title></section><section id="sec_bibl"><title>Bibliography</title></section></toc>