<?xml version="1.0" encoding="UTF-8"?><toc><section id="foreword.nat"><title>Nationales Vorwort</title></section><section id="foreword.reg"><title>Europäisches Vorwort</title></section><section id="sub-endorsement.notice"><title>Anerkennungsnotiz</title></section><section id="foreword.int"><title>Vorwort</title></section><section id="introduction.int"><title>Einleitung</title></section><section id="sub-1"><label>1</label><title>* Anwendungsbereich</title></section><section id="sub-2"><label>2</label><title>Normative Verweisungen</title></section><section id="sub-3"><label>3</label><title>Begriffe</title><section id="sub-3.1"><label>3.1</label><title>Begleitpapiere</title></section><section id="sub-3.2"><label>3.2</label><title>automatisches druckgesteuertes Wiederbelebungsgerät</title></section><section id="sub-3.3"><label>3.3</label><title>automatisches zeitgesteuertes Wiederbelebungsgerät</title></section><section id="sub-3.4"><label>3.4</label><title>automatisches volumengesteuertes Wiederbelebungsgerät</title></section><section id="sub-3.5"><label>3.5</label><title>Herz-Lungen-Reanimation</title></section><section id="sub-3.6"><label>3.6</label><title>deutlich lesbar</title></section><section id="sub-3.7"><label>3.7</label><title>* abgegebenes Volumen</title></section><section id="sub-3.8"><label>3.8</label><title>Lungenautomat</title></section><section id="sub-3.9"><label>3.9</label><title>Ersthelfer</title></section><section id="sub-3.10"><label>3.10</label><title>gasbetriebenes Notfall-WiederbelebungsgerätWiederbelebungsgerät</title></section><section id="sub-3.11"><label>3.11</label><title>unbeabsichtigter positiver endexspiratorischer Druckunbeabsichtigter PEEP</title></section><section id="sub-3.12"><label>3.12</label><title>Zwischenschlauch</title></section><section id="sub-3.13"><label>3.13</label><title>Handbeatmungsgerät</title></section><section id="sub-3.14"><label>3.14</label><title>Minutenvolumen</title></section><section id="sub-3.15"><label>3.15</label><title>Bediener</title></section><section id="sub-3.16"><label>3.16</label><title>patientengesteuertes Wiederbelebungsgerät</title></section><section id="sub-3.17"><label>3.17</label><title>Patientensteuerung</title></section><section id="sub-3.18"><label>3.18</label><title>Patientenventil</title></section><section id="sub-3.19"><label>3.19</label><title>Druckbegrenzungsvorrichtung</title></section><section id="sub-3.20"><label>3.20</label><title>Atemsystem des Wiederbelebungsgeräts</title></section><section id="sub-3.21"><label>3.21</label><title>Totraum des Wiederbelebungsgeräts</title></section><section id="sub-3.22"><label>3.22</label><title>Wiederbelebungsgeräte-Satz</title></section><section id="sub-3.23"><label>3.23</label><title>Gefährdung</title></section><section id="sub-3.24"><label>3.24</label><title>erster Fehler</title></section></section><section id="sub-4"><label>4</label><title>Allgemeine Anforderungen</title><section id="sub-4.1"><label>4.1</label><title>Allgemeines</title></section><section id="sub-4.2"><label>4.2</label><title>Weitere Prüfverfahren</title></section><section id="sub-4.3"><label>4.3</label><title>Annahmekriterien</title></section></section><section id="sub-5"><label>5</label><title>Anforderungen an die Konstruktion</title><section id="sub-5.1"><label>5.1</label><title>Allgemeines</title><section id="sub-5.1.1"><label>5.1.1</label><title>Konstruktionswerkstoffe</title></section><section id="sub-5.1.2"><label>5.1.2</label><title>Oberflächen, Ecken und Kanten</title></section><section id="sub-5.1.3"><label>5.1.3</label><title>Austreten von Substanzen</title></section><section id="sub-5.1.4"><label>5.1.4</label><title>Atemschläuche</title></section><section id="sub-5.1.5"><label>5.1.5</label><title>Lieferung von sterilen Komponenten</title></section><section id="sub-5.1.6"><label>5.1.6</label><title>* Atemsystemfilter</title></section><section id="sub-5.1.7"><label>5.1.7</label><title>Anordnung der Funktionen</title></section><section id="sub-5.1.8"><label>5.1.8</label><title>Schutz gegen versehentliche Einstellungen</title></section><section id="sub-5.1.9"><label>5.1.9</label><title>Auswahlschalter/Bedienelemente</title></section><section id="sub-5.1.10"><label>5.1.10</label><title>Genauigkeit der Betriebsdaten</title></section><section id="sub-5.1.11"><label>5.1.11</label><title>* Wiederbelebungsgeräte-Satz</title></section></section><section id="sub-5.2"><label>5.2</label><title>Verbindungsstücke</title><section id="sub-5.2.1"><label>5.2.1</label><title>Anschluss an das Versorgungssystem für medizinische Gase</title></section><section id="sub-5.2.2"><label>5.2.2</label><title>Anschluss an eine Hochdruckgas-Eintrittsöffnung</title></section><section id="sub-5.2.3"><label>5.2.3</label><title>Verbindungsstück für die Patientenanschlussöffnung</title></section><section id="sub-5.2.4"><label>5.2.4</label><title>Verbindungsstück für die Gesichtsmaske</title></section><section id="sub-5.2.5"><label>5.2.5</label><title>* Verbindungsstück für die Gasaustrittsöffnung</title></section><section id="sub-5.2.6"><label>5.2.6</label><title>Verbindungsstücke für die Einatemschenkel des Wiederbelebungsgerät</title></section><section id="sub-5.2.7"><label>5.2.7</label><title>Eintrittsöffnung für Notluft</title></section></section></section><section id="sub-6"><label>6</label><title>Betriebliche Anforderungen</title><section id="sub-6.1"><label>6.1</label><title>Allgemeines</title><section id="sub-6.1.1"><label>6.1.1</label><title>* Patientenventilfunktion nach Kontamination mit Erbrochenem</title></section><section id="sub-6.1.2"><label>6.1.2</label><title>Reinigung, und Sterilisation oder Desinfektion</title></section><section id="sub-6.1.3"><label>6.1.3</label><title>* Funktionsprüfung nach der Wiedermontage</title><section id="sub-6.1.3.1"><label>6.1.3.1</label><title>Wiedermontage</title></section><section id="sub-6.1.3.2"><label>6.1.3.2</label><title>Funktionsprüfung</title></section></section><section id="sub-6.1.4"><label>6.1.4</label><title>Verbindungsstücke für durchflussrichtungsempfindliche Bauteile</title></section></section><section id="sub-6.2"><label>6.2</label><title>Widerstandsfähigkeit gegen Umwelteinflüsse</title><section id="sub-6.2.1"><label>6.2.1</label><title>* Lager- und Betriebsbedingungen</title><section id="sub-6.2.1.1"><label>6.2.1.1</label><title>Lagerung</title></section><section id="sub-6.2.1.2"><label>6.2.1.2</label><title>Betriebsbedingungen</title></section></section></section><section id="sub-6.3"><label>6.3</label><title>Widerstandsfähigkeit gegen typischen Gebrauch</title><section id="sub-6.3.1"><label>6.3.1</label><title>Mechanischer Schock</title><section id="sub-6.3.1.1"><label>6.3.1.1</label><title>* Fallprüfung</title></section></section><section id="sub-6.3.2"><label>6.3.2</label><title>Spritzwasserfestigkeit</title></section><section id="sub-6.3.3"><label>6.3.3</label><title>* Eintauchen in Wasser</title></section></section><section id="sub-6.4"><label>6.4</label><title>Größe und Masse</title><section id="sub-6.4.1"><label>6.4.1</label><title>* Größe</title></section><section id="sub-6.4.2"><label>6.4.2</label><title>* Masse</title></section></section><section id="sub-6.5"><label>6.5</label><title>Gasversorgung</title><section id="sub-6.5.1"><label>6.5.1</label><title>Gasflaschen und Flaschenventil</title></section><section id="sub-6.5.2"><label>6.5.2</label><title>Unverlierbarer Flaschenventilschlüssel</title></section><section id="sub-6.5.3"><label>6.5.3</label><title>Flaschenregler</title></section><section id="sub-6.5.4"><label>6.5.4</label><title>Externe Stromversorgung</title></section><section id="sub-6.5.5"><label>6.5.5</label><title>Dauerhaft angeschlossenes Wiederbelebungsgerät</title></section><section id="sub-6.5.6"><label>6.5.6</label><title>* Zwischenschlauch</title></section><section id="sub-6.5.7"><label>6.5.7</label><title>Gasbehälterkapazität</title></section></section></section><section id="sub-7"><label>7</label><title>Leistung</title><section id="sub-7.1"><label>7.1</label><title>Beatmungsanforderungen</title><section id="sub-7.1.1"><label>7.1.1</label><title>* Konzentration des abgegebenen Sauerstoffs</title></section><section id="sub-7.1.2"><label>7.1.2</label><title>* Widerstand gegen spontane Atmung</title><section id="sub-7.1.2.1"><label>7.1.2.1</label><title>Allgemeines</title></section><section id="sub-7.1.2.2"><label>7.1.2.2</label><title>Inspirationswiderstand während der Exspirationsphase des Wiederbelebungsgeräts</title></section><section id="sub-7.1.2.3"><label>7.1.2.3</label><title>Spontane Atmung mit Gaseingangsdruck außerhalb des Bemessungsbereichs</title></section><section id="sub-7.1.2.4"><label>7.1.2.4</label><title>Exspirationswiderstand</title></section></section><section id="sub-7.1.3"><label>7.1.3</label><title>* Unbeabsichtigter PEEP</title></section><section id="sub-7.1.4"><label>7.1.4</label><title>* Unbeabsichtigt anhaltender Exspirationsdruck</title></section><section id="sub-7.1.5"><label>7.1.5</label><title>* Totraum des Wiederbelebungsgeräts und Totraum des Atemwegszubehörs</title></section></section><section id="sub-7.2"><label>7.2</label><title>* Beatmungsleistung</title><section id="sub-7.2.1"><label>7.2.1</label><title>Allgemeines</title><section id="sub-7.2.1.1"><label>7.2.1.1</label><title>Handbeatmungsgerät</title></section><section id="sub-7.2.1.2"><label>7.2.1.2</label><title>Automatisches druckgesteuertes Wiederbelebungsgerät</title></section><section id="sub-7.2.1.3"><label>7.2.1.3</label><title>Automatisches zeit- oder volumengesteuertes Wiederbelebungsgerät</title></section><section id="sub-7.2.1.4"><label>7.2.1.4</label><title>Patientengesteuertes Wiederbelebungsgerät</title></section><section id="sub-7.2.1.5"><label>7.2.1.5</label><title>Wiederbelebungsgerät mit Lungenautomat</title></section></section><section id="sub-7.2.2"><label>7.2.2</label><title>* Abgegebenes Volumen (V)</title></section><section id="sub-7.2.3"><label>7.2.3</label><title>* Einheitlichkeit des abgegebenen Volumens</title></section><section id="sub-7.2.4"><label>7.2.4</label><title>Druckbegrenzung bei bestimmungsgemäßem Gebrauch</title></section><section id="sub-7.2.5"><label>7.2.5</label><title>Druckbegrenzung bei ersten Fehler</title></section><section id="sub-7.2.6"><label>7.2.6</label><title>* Alarmsignal für die Aktivierung der Druckbegrenzung</title></section><section id="sub-7.2.7"><label>7.2.7</label><title>* Inspirationsdurchfluss</title></section><section id="sub-7.2.8"><label>7.2.8</label><title>Bedienung des Handauslösers an einem Handbeatmungsgerät</title></section><section id="sub-7.2.9"><label>7.2.9</label><title>Lungenautomat</title><section id="sub-7.2.9.1"><label>7.2.9.1</label><title>Allgemeines</title></section><section id="sub-7.2.9.2"><label>7.2.9.2</label><title>Druckschwellwert zur Auslösung des Durchflusses</title></section><section id="sub-7.2.9.3"><label>7.2.9.3</label><title>Spitzeninspirationsdurchfluss</title></section><section id="sub-7.2.9.4"><label>7.2.9.4</label><title>Beendigungsdruck</title></section><section id="sub-7.2.10"><label>7.2.10</label><title>* Patientengesteuertes Wiederbelebungsgerät</title></section></section></section></section><section id="sub-8"><label>8</label><title>Kennzeichnung, Aufschriften und Unterlagen</title><section id="sub-8.1"><label>8.1</label><title>Allgemeines</title><section id="sub-8.1.1"><label>8.1.1</label><title>Bedingungen</title></section><section id="sub-8.1.2"><label>8.1.2</label><title>Maßeinheiten</title></section></section><section id="sub-8.2"><label>8.2</label><title>Aufschrift</title><section id="sub-8.2.1"><label>8.2.1</label><title>* Lesbarkeit der Kennzeichnung</title></section><section id="sub-8.2.2"><label>8.2.2</label><title>* Dauerhaftigkeit der Aufschriften</title></section><section id="sub-8.2.3"><label>8.2.3</label><title>Identifikation</title></section><section id="sub-8.2.4"><label>8.2.4</label><title>Bedienelemente und Angaben</title></section><section id="sub-8.2.5"><label>8.2.5</label><title>Angabe der Einstellung der Druckbegrenzungsvorrichtung</title></section><section id="sub-8.2.6"><label>8.2.6</label><title>Angabe der Verwendung einer Funktion, die die Leistung beeinflusst</title></section><section id="sub-8.2.7"><label>8.2.7</label><title>Angabe der pneumatischen Nennleistung</title></section><section id="sub-8.2.8"><label>8.2.8</label><title>Durchflussrichtungsempfindliches Bauteil</title></section><section id="sub-8.2.9"><label>8.2.9</label><title>Hinweis auf Latex</title></section><section id="sub-8.2.10"><label>8.2.10</label><title>Angabe des Schutzes gegen Wassereintritt</title></section></section><section id="sub-8.3"><label>8.3</label><title>Vom Hersteller bereitgestellte Angaben zu Betrieb und Wartung</title><section id="sub-8.3.1"><label>8.3.1</label><title>Allgemeines</title></section><section id="sub-8.3.2"><label>8.3.2</label><title>Inhalt</title></section></section></section><section id="sub-a"><label>Anhang A</label><title>Begründung (informativ)</title></section><section id="sub-b"><label>Anhang B</label><title>Prüfverfahren (normativ)</title><section id="sub-b.1"><label>B.1</label><title>Prüfbedingungen</title><section id="sub-b.1.1"><label>B.1.1</label><title>Allgemeines</title></section><section id="sub-b.1.2"><label>B.1.2</label><title>Konditionierung des Wiederbelebungsgeräte-Satzes und der Prüfeinrichtung</title></section><section id="sub-b.1.3"><label>B.1.3</label><title>Referenzbedingungen</title></section></section><section id="sub-b.2"><label>B.2</label><title>Prüfeinrichtung</title><section id="sub-b.2.1"><label>B.2.1</label><title>Allgemeines</title></section><section id="sub-b.2.2"><label>B.2.2</label><title>Elemente der Prüfeinrichtung</title></section></section><section id="sub-b.3"><label>B.3</label><title>Prüfverfahren</title><section id="sub-b.3.1"><label>B.3.1</label><title>Ventilfunktion nach Kontamination mit Erbrochenem</title><section id="sub-b.3.1.1"><label>B.3.1.1</label><title>Prüfmaterial</title></section><section id="sub-b.3.1.2"><label>B.3.1.2</label><title>Durchführung</title></section></section><section id="sub-b.3.2"><label>B.3.2</label><title>Demontage und Wiedermontage</title></section><section id="sub-b.3.3"><label>B.3.3</label><title>Lager- und Betriebsbedingungen</title><section id="sub-b.3.3.1"><label>B.3.3.1</label><title>Allgemeines</title></section><section id="sub-b.3.3.2"><label>B.3.3.2</label><title>Durchführung</title></section></section><section id="sub-b.3.4"><label>B.3.4</label><title>Fallprüfung</title></section><section id="sub-b.3.5"><label>B.3.5</label><title>Eintauchen in Wasser</title></section><section id="sub-b.3.6"><label>B.3.6</label><title>Gasbehälterkapazität</title></section><section id="sub-b.3.7"><label>B.3.7</label><title>Konzentration des abgegebenen Sauerstoffs</title></section><section id="sub-b.3.8"><label>B.3.8</label><title>Widerstand gegen spontane Atmung</title><section id="sub-b.3.8.1"><label>B.3.8.1</label><title>Inspirationswiderstand</title></section><section id="sub-b.3.8.2"><label>B.3.8.2</label><title>Spontane Atmung bei Leistung außerhalb des Bemessungsbereichs</title></section><section id="sub-b.3.8.3"><label>B.3.8.3</label><title>Exspirationswiderstand</title></section></section><section id="sub-b.3.9"><label>B.3.9</label><title>Unbeabsichtigter PEEP</title></section><section id="sub-b.3.10"><label>B.3.10</label><title>Unbeabsichtigt anhaltender Exspirationsdruck</title></section><section id="sub-b.3.11"><label>B.3.11</label><title>Abgegebenes Volumen</title></section><section id="sub-b.3.12"><label>B.3.12</label><title>Einheitlichkeit des abgegebenen Volumens</title></section><section id="sub-b.3.13"><label>B.3.13</label><title>Druckbegrenzung und Hochdruckalarm</title></section><section id="sub-b.3.14"><label>B.3.14</label><title>Inspirationsdurchfluss</title></section><section id="sub-b.3.15"><label>B.3.15</label><title>Bedienung des manuellen Auslösers</title></section><section id="sub-b.3.16"><label>B.3.16</label><title>Lungenautomat</title><section id="sub-b.3.16.1"><label>B.3.16.1</label><title>Aufbau</title></section><section id="sub-b.3.16.2"><label>B.3.16.2</label><title>Durchfluss-Schwellenwert</title></section><section id="sub-b.3.16.3"><label>B.3.16.3</label><title>Spitzendurchfluss</title></section><section id="sub-b.3.16.4"><label>B.3.16.4</label><title>Durchfluss-Beendigung</title></section></section><section id="sub-b.3.17"><label>B.3.17</label><title>Patientengesteuertes Wiederbelebungsgerät</title></section></section></section><section id="sub-c"><label>Anhang C</label><title>Zusammenhang zwischen diesem Teil von ISO 10651 und den Richtlinien zur Herz-Lungen-Reanimation (informativ)</title></section><section id="sub-d"><label>Anhang D</label><title>Abschnitte dieses Teils von ISO 10651, die sich mit den wesentlichen Grundsätzen befassen (informativ)</title></section><section id="sub-e"><label>Anhang E</label><title>Terminologie — Verzeichnis definierter Begriffe (informativ)</title></section><section id="sub-annex.bibliography.int"><title>Literaturhinweise</title></section><section id="sub-na"><label>Nationaler Anhang NA</label><title>Literaturhinweise (informativ)</title></section></toc>