Standard Guide for Measuring and Estimating Quantities of Insulated Piping and Components

Standard [CURRENT]

ASTM C 1409:2012

Standard Guide for Measuring and Estimating Quantities of Insulated Piping and Components

Publication date
2012 reapproved: 2018
Original language
English
Pages
8

from 77.00 EUR VAT included

from 71.96 EUR VAT excluded

Format and language options

PDF download 1
  • 77.00 EUR

  • 92.50 EUR

Shipment (3-5 working days)
  • 85.70 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

Document with DRM – more on DRM

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2012 reapproved: 2018
Original language
English
Pages
8
Loading recommended items...

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description

1.1 This guide defines the components of an insulated piping system to be measured or counted to determine quantities and pricing for unit price contracts or extra work. 1.2 Pricing may be done through unit pricing for each item by pipe size, type of insulation system, insulation thickness, double or multilayer insulation, type of weatherproofing or jacketing, and pressure rating (if necessary) or through component (fitting) factor or multipliers. 1.2.1 Component (fitting) factors or multipliers, which are multipliers times the straight length of piping as shown in Table 1 , determine relative prices for each component not within the scope of this guide. These factors or multipliers are to be determined by the insulating contractor relative to the given situation and insulation system specification. TABLE 1 Piping Unit Price Schedule, Hot Insulation, 0.016-in. Thick Aluminum Jacketing, Cost per Linear Foot (All Materials and Labor Necessary for a Complete Installation) 11/2 2 21/2 3 31/2 4 31/2 DL A , B 4 DL A , B 4 DL A , B 2 and under 21/2 3 31/2 4 6 8 10 12 14 16 18 20 24 30 Over 30 and Equipment A DL = Double layer. B In some insulation systems, double-layer insulation may occur at smaller thickness. 1.2.2 It is suggested that only one type of pricing be used on a project. 1.2.3 The values stated in inch-pound units are to be regarded as the standard.
Also available in
Loading recommended items...