Standard Practice for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Post Backfill
new

Standard [NEW]

ASTM C 1964:2026

Standard Practice for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Post Backfill

Publication date
2026
Original language
English
Pages
3

from 68.50 EUR VAT included

from 64.02 EUR VAT excluded

Format and language options

PDF download 1
  • 68.50 EUR

Shipment (3-5 working days)
  • 76.20 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

Document with DRM – more on DRM

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2026
Original language
English
Pages
3
DOI
https://dx.doi.org/10.1520/C1964-26

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description

1.1 This practice covers procedures for testing precast concrete manhole sections when using the vacuum test method to demonstrate the integrity of the installed materials and the construction procedures. This practice is used for testing concrete manhole sections utilizing mortar, mastic, or gasketed joints. 1.2 This practice is intended to be used as a test to enable the installer to demonstrate the condition of the concrete manholes post backfill. Its purpose is to avoid overloading the manhole with pressure in excess of 10 in. Hg (33.86 kPa). 1.3 This practice is unsuitable for structures with pipe stubs installed unless restrained per the requirements of this standard. 1.3.1 Users are hereby cautioned that overloading can result in catastrophic failure that can seriously damage the system causing major rehabilitation costs, including rendering the system unusable. 1.3.2 This practice is not suitable for non-cylindrical manholes. Note 1: Vacuum test criteria presented in this practice are similar to those in general use. The test and criteria have been widely and successfully used in testing manholes. Note 2: The user of this practice is advised that no correlation has been found between vacuum (air) and hydrostatic tests. Note 3: If the test requires the full pressure load, 10 in. Hg (33.86 kPa) to be applied the site should be de-watered and the test run. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS

23.040.50

DOI

https://dx.doi.org/10.1520/C1964-26
Also available in
Loading recommended items...
Loading recommended items...
Loading recommended items...