Standard Practice for Calibration of Type S Pitot Tubes

Standard [CURRENT]

ASTM D 3796:2009

Standard Practice for Calibration of Type S Pitot Tubes

German title
Kalibrierung von Pitotrohren Typ S
Publication date
2009 reapproved: 2024
Original language
English
Pages
13

from 85.60 EUR VAT included

from 80.00 EUR VAT excluded

Format and language options

PDF download 1
  • 85.60 EUR

  • 102.80 EUR

Shipment (3-5 working days)
  • 95.20 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

Document with DRM – more on DRM

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2009 reapproved: 2024
Original language
English
Pages
13
DOI
https://dx.doi.org/10.1520/D3796-09R24E01
Loading recommended items...

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description

1.1 This practice covers the determination of Type S pitot tube coefficients in the gas velocity range from 305 to 1524 m/min or 5.08 to 25.4 m/s (1000 to 5000 ft/min). The method applies both to the calibration of isolated Type S pitot tubes (see 5.1), and pitobe assemblies. 1.2 This practice outlines procedures for obtaining Type S pitot tube coefficients by calibration at a single-velocity setting near the midpoint of the normal working range. Type S pitot coefficients obtained by this method will generally be valid to within ±3 % over the normal working range. If a more precise correlation between Type S pitot tube coefficient and velocity is desired, multivelocity calibration technique (Annex A1) should be used. The calibration coefficients determined for the Type S pitot tube by this practice do not apply in field use when the flow is nonaxial to the face of the tube. 1.3 This practice may be used for the calibration of thermal anemometers for gas velocities in excess of 3 m/s (10 ft/s). 1.4 The values stated in SI units are to be regarded as standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

ICS

17.020

DOI

https://dx.doi.org/10.1520/D3796-09R24E01
Also available in
Loading recommended items...