Standard Practice for (Analytical Procedure) Tests of Anisotropic Unconfined Aquifers by Neuman Method

Standard [CURRENT]

ASTM D 5920/D 5920M:2020

Standard Practice for (Analytical Procedure) Tests of Anisotropic Unconfined Aquifers by Neuman Method

Publication date
2020
Original language
English
Pages
9

from 77.00 EUR VAT included

from 71.96 EUR VAT excluded

Format and language options

PDF download 1
  • 77.00 EUR

  • 92.50 EUR

Shipment (3-5 working days)
  • 85.70 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

Document with DRM – more on DRM

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2020
Original language
English
Pages
9
DOI
https://dx.doi.org/10.1520/D5920_D5920M-20

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description

1.1 This practice covers an analytical procedure for determining the transmissivity, storage coefficient, specific yield, and horizontal-to-vertical hydraulic conductivity ratio of an unconfined aquifer. It is used to analyze the drawdown of water levels in piezometers and partially or fully penetrating observation wells during pumping from a control well at a constant rate. 1.2 The analytical procedure given in this practice is used in conjunction with Guide D4043 and Test Method D4050 . 1.3 The valid use of the Neuman method is limited to determination of transmissivities for aquifers in hydrogeologic settings with reasonable correspondence to the assumptions of the theory. 1.4 Units- The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. Reporting of test result in units other than SI shall not be regarded as nonconformance with this standard. 1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026 . 1.5.1 The procedures used to specify how data are collected/recorded or calculated in the standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining the data, special purpose studies, or any considerations for the user's objectives; and it is common practice to increase or reduce significant digits of reported data to be commensurate with these considerations. It is beyond the scope of this standard to consider significant digits used in analysis methods for engineering data. 1.6 This practice offers a set of instructions for performing one or more specific operations. This document cannot replace education or experience and should be used in conjunction with professional judgment. Not all aspects of the practice may be applicable in all circumstances. This ASTM standard is not intended to represent or replace the standard of care by which the adequacy of a given professional service must be judged, nor should this document be applied without the consideration of a project's many unique aspects. The word "Standard" in the title of this document means only that the document has been approved through the ASTM consensus process. 1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.