Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs

Standard [CURRENT]

ASTM E 2461:2022

Standard Practice for Determining the Thickness of Glass in Airport Traffic Control Tower Cabs

Publication date
2022
Original language
English
Pages
98

from 140.20 EUR VAT included

from 131.03 EUR VAT excluded

Format and language options

PDF download 1
  • 140.20 EUR

  • 168.30 EUR

Shipment (3-5 working days)
  • 155.90 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

Document with DRM – more on DRM

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2022
Original language
English
Pages
98
DOI
https://dx.doi.org/10.1520/E2461-22

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description

1.1 This practice covers the determination of the thickness of glass installed in airport traffic control towers (ATCT) to resist a specified design loading with a selected probability of breakage less than or equal to either 1 lite per 1000 or 4 lites per 1000 at the first occurrence of the design wind loading. 1.2 The procedures apply to common outward sloping cab glass designs for which the specified loads do not exceed 15 kPa (313 psf). 1.3 The procedures assume control tower cab glass has an aspect ratio no greater than 3. 1.4 The procedures assume control tower cab glass has an area no less than 1.86 m2 (20 ft2). 1.5 The use of the procedures assumes the following: 1.5.1 Monolithic and laminated glass installed in ATCTs shall have continuous lateral support along two parallel edges, along any three edges, or along all four edges; 1.5.2 Insulating glass shall have continuous lateral support along all four edges; and 1.5.3 Supported glass edges are simply supported and free to slip in plane. 1.6 The procedures do not apply to any form of wired, patterned, etched, sandblasted, or glass types with surface treatments that reduce the glass strength. 1.7 The procedures do not apply to drilled, notched, or grooved glass. 1.8 The procedures address the determination of thickness and construction type to resist a specified design wind load at a selected probability of breakage. The final glass thickness and construction determined also depends upon a variety of other factors (see 5.4 ). 1.9 These procedures do not address blast loading on glass. 1.10 These procedures do not apply to triple-glazed insulating glass units. 1.11 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard. 1.12 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and to determine the applicability of regulatory limitations prior to use. 1.13 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS

81.040.20

DOI

https://dx.doi.org/10.1520/E2461-22
Also available in
Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...