Standard Test Method for Using Calorimeters for Total Dose Measurements in Pulsed Linear Accelerator or Flash X-ray Machines

Standard [CURRENT]

ASTM F 526:2021

Standard Test Method for Using Calorimeters for Total Dose Measurements in Pulsed Linear Accelerator or Flash X-ray Machines

Publication date
2021
Original language
English
Pages
13

from 85.60 EUR VAT included

from 80.00 EUR VAT excluded

Format and language options

PDF download 1
  • 85.60 EUR

  • 102.80 EUR

Shipment (3-5 working days)
  • 95.20 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

Document with DRM – more on DRM

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2021
Original language
English
Pages
13
DOI
https://dx.doi.org/10.1520/F0526-21
Loading recommended items...

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description

1.1 This test method covers a calorimetric measurement of the total absorbed dose delivered by a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode). The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are "thin" compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which ( 1 ) the dose delivered in a single pulse is 5 Gy(matl) 2 [500 rd (matl)] or greater, or ( 2 ) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. The units for the total absorbed dose delivered to a material require the specification of the material and the notation "matl" refers to the active material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity, and the thermal time constant of the calorimeter. 1.3 A determination of the total dose is made directly for the material of which the calorimeter block is made. The total dose in other materials can be calculated from this measured value using Eq 3 presented in this test method. The need for such calculations and the choice of materials for which calculations are to be made shall be subject to agreement by the parties to the test. 1.4 The values stated in SI units are to be regarded as the standard. The values in parenthesis are provided for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS

17.240

DOI

https://dx.doi.org/10.1520/F0526-21
Also available in
Loading recommended items...