Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (IEC 60601-2-50:2020 + AMD1:2023); German version EN IEC 60601-2-50:2021 + A1:2023

Standard [CURRENT]

DIN EN IEC 60601-2-50:2024-09

VDE 0750-2-50:2024-09

Medical electrical equipment - Part 2-50: Particular requirements for the basic safety and essential performance of infant phototherapy equipment (IEC 60601-2-50:2020 + AMD1:2023); German version EN IEC 60601-2-50:2021 + A1:2023

German title
Medizinische elektrische Geräte - Teil 2-50: Besondere Festlegungen für die Sicherheit einschließlich der wesentlichen Leistungsmerkmale von Säuglings-Phototherapiegeräten (IEC 60601-2-50:2020 + AMD1:2023); Deutsche Fassung EN IEC 60601-2-50:2021 + A1:2023
Publication date
2024-09
Original language
German
Pages
41

89.53 EUR VAT included

83.67 EUR VAT excluded

Format and language options

Shipment (3-5 working days)
  • 89.53 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2024-09
Original language
German
Pages
41

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

These particular requirements set out safety requirements for infant phototherapy equipment, but alternate methods of compliance with a specific clause by demonstrating equivalent safety will not be judged as non-compliant if the manufacturer has demonstrated in his risk management file that the risk presented by the hazard has been found to be of an acceptable level when weighed against the benefit of treatment from the device. The purpose of these particular requirements is to establish specific requirements for the basic safety and essential performance characteristics of infant phototherapy equipment, to reduce hazards to patients and operators as much as possible, and to specify tests that can be used to verify compliance with the requirements. This document does not apply to: This document does not apply to: - devices supplying heat via blankets, pads or mattresses in medical use; for information, see IEC 60601-2-35; - infant incubators; for information, see IEC 60601-2-19; - infant transport incubators, for information see IEC 60601-2-20; - infant radiant warmers, for information see IEC 60601-2-21. The standard differs from DIN EN IEC 60601-2-50 (VDE 0750-2-50): 2022-08 as follows: a) the clause "Normative references" has been revised and supplemented; b) individual terms and definitions have been revised and the reference to IEC 60601-1:2005/AMD2:2020 added; c) Table 201.101 updated; d) in the clause "Electromagnetic disturbances - Requirements and tests", the reference to IEC 60601-1-2:2014 and IEC 60601-1-2:2014/AMD1:2020 has been added; e) Annex AA has been revised and supplemented. These particular requirements set out requirements for the safety of infant phototherapy equipment.