DIN V 18599-7:2016-10

Energy efficiency of buildings - Calculation of the net, final and primary energy demand for heating, cooling, ventilation, domestic hot water and lighting - Part 7: Final energy demand of air-handling and air-conditioning systems for non-residential buildings

German title
Energetische Bewertung von Gebäuden - Berechnung des Nutz-, End- und Primärenergiebedarfs für Heizung, Kühlung, Lüftung, Trinkwarmwasser und Beleuchtung - Teil 7: Endenergiebedarf von Raumlufttechnik- und Klimakältesystemen für den Nichtwohnungsbau
Publication date
2016-10
Original language
German
Pages
167
Procedure
Pre-Standard

Please select

from 291.10 EUR VAT included

from 272.06 EUR VAT excluded

Purchasing options

PDF download 1
  • 291.10 EUR

Shipment (3-5 working days) 1
  • 351.70 EUR

1

 Attention: Document withdrawn!

Online service subscriptions

This document also features in an online service. Online services not only give you electronic access to collections of standards, they contain lots of extra information too (such as directives, legal texts, commentaries, etc.). There are automatic updates on a regular basis – and online services also give you large savings compared with the cost of purchasing standards individually.

Suitable online services
Publication date
2016-10
Original language
German
Pages
167
Procedure
Pre-Standard

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

DIN V 18599-7 applies to heating, ventilation and air conditioning systems of non-residential buildings and uses the energy need for room conditioning calculated as described in DIN V 18599-2 and the energy need for air handling (heating, cooling and humidification) calculated as described in DIN V 18599-3. The methods described enable calculation of the heat output for heating functions of the HVAC system. The values calculated are output values for the calculations described in DIN V 18599-5.
Furthermore, the (net) generator cooling output for room conditioning and air handling cooling functions is determined and the delivered energy for refrigeration equipment (electrical energy) and the generator heat output for the thermal chillers are calculated with the aid of a method for cooling generation based on characteristic values; these are then used as output values for the calculations in DIN V 18599-5.
In the same way, the final energy necessary for steam humidification (electrical energy, gas and oil) is calculated.
Additional methods for calculating the energy requirements of the chilled water and cooling-water distribution pumps as well as of any other pumps and ancillary drives needed are described.
DIN V 18599-7 has been approved by NA 005-12-01 GA "Gemeinschaftsarbeitsausschuss NABau/FNL/NHRS: Energetische Bewertung von Gebäuden" ("Joint Working Committee NABau/FNL/NHRS: Energy efficiency of buildings") and published as a prestandard.

Content
ICS
91.120.10, 91.140.30
Replacement amendments

This document replaces DIN V 18599-7:2011-12 .

This document has been replaced by: DIN V 18599-7:2018-09 .