Standard Practice for On-Site Identification of Firestop Systems and Judgments

Standard [CURRENT]

ASTM E 3456:2026

Standard Practice for On-Site Identification of Firestop Systems and Judgments

Publication date
2026
Accessibility
Original language
English
Pages
6

from 77.00 EUR VAT included

from 71.96 EUR VAT excluded

Format and language options

PDF download 1
  • 77.00 EUR

  • 92.50 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

Document with DRM – more on DRM

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2026
Original language
English
Pages
6
DOI
https://dx.doi.org/10.1520/E3456-26
Loading recommended items...

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Short description

1.1 This practice covers the identification requirements for installed firestop systems (FS), fire-resistive joint systems (FRJS), perimeter fire containment systems (PFCS), and continuity head-of-wall joint systems (CHWJS). These systems are installed on, in, or between fire resistance rated wall assemblies, fire resistance rated horizontal assemblies, non-rated floor or roof assemblies, or curtain wall assemblies, or a combination thereof, using the methods described in systems tested in accordance with the below standards, judgments (EJ), code evaluation detail (CED), or equivalent fire-resistance-rated assemblies (EFRRA), technical evaluation (TE) based on the standards. Type of Protection Standard(s) Penetration Firestop System (FS) Test Method E814 (UL 1479) Fire-Resistive Joint System (FRJS) Test Method E1966 (UL 2079) Perimeter Fire Containment System (PFCS) Test Method E2307 Continuity Head-of-Wall Joint System (CHWJS) Test Method E2837 1.2 The purpose of the firestop identification labels/tags is to provide permanent information relating to the specific tested system, judgments (EJ), code evaluation detail (CED), equivalent fire-resistance-rated assembly (EFRRA), or technical evaluation (TE) used to protect each penetration, joint, or breach. 1.3 Identification shall be established by means of firestop identification labels/tags being affixed to or adjacent to the installed system. Note 1: The International Building Code, and possibly other building codes, requires identification on fire-resistance-rated wall assemblies using 3 in. (76.2 mm) tall by 3/8 in. (9.5 mm) lettering. Identification of fire ratings is also required for fire-rated glazing, at fire-dampered ducts, and on fire-rated doors. 1.4 This practice is not intended to establish any performance criteria for installed firestop systems, fire-resistive joint systems, perimeter fire barrier systems, spandrel-panel systems, and continuity head-of-wall joint systems protected using tested systems, judgments, equivalent fire-resistance-rated assemblies, or technical evaluations. 1.5 The text of this practice references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered requirements of the standard. 1.6 Units- The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.7 Summary- Due to the fact that firestop identification labels/tags, etc. are being specified and used, a standard establishing consistent requirements for placement locations and minimum required information makes sense to all involved in the process. Such a standard will result in more efficient inspections during construction and during the maintenance cycles of the building. 1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

ICS

13.220.01

DOI

https://dx.doi.org/10.1520/E3456-26
Also available in