This document specifies the characteristics of single-pole circuit breakers, temperature compensated with a rated current from 1 A to 25 A, used in aircraft on-board circuits at a temperature between -55 °C and 125 °C and at an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single push button (actuator), with delayed action "trip-free" tripping with a polarized signal contact which is open when main contacts are closed, and inversely. They will continue to function up to the short-circuit current. The EN 2995-006 standard has been prepared by the standardization organization ASD-STAN of the AeroSpace and Defence Industries Association of Europe (ASD) with the participation of German experts at DIN Standards Committee Aerospace (NL). The responsible German standardization committee is Working Committee NA 131-04-05 AA "Schalter, Relais und Schutzgeräte" ("Switch, relays and protection devices") at DIN Standards Committee Aerospace (NL).