This part of IEC 61300-3-14 describes a method to measure the error and repeatability of the attenuation value settings of a variable optical attenuator (VOA). There are two control technologies for VOAs, manually controlled and electrically controlled. This standard covers both control technologies of VOAs and also covers both single-mode and multimode fibre VOAs. The guideline for the execution of the measurements and calculations as well as an example for a sample measurement record provides manufacturers and test laboratories with defined information and investment security. The responsible committee is DKE/UK 412.7 "LWL-Verbindungstechnik und passive optische Komponenten" ("Fibre optic interconnecting devices and passive optical components") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.
This document replaces DIN EN 61300-3-14:2007-08 .
This document has been replaced by: DIN EN IEC 61300-3-14:2026-07 .