To our valued customers,

At last: 

Beuth Verlag is now DIN Media. 

You can find out more about our new name and the reasons behind it here.

To use our new website without any hiccups, please clear your browser cache. 

Yours sincerely,

DIN Media

Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Standard [CURRENT]

DIN EN 61558-2-15:2012-09

VDE 0570-2-15:2012-09

Safety of transformers, reactors, power supply units and combinations thereof - Part 2-15: Particular requirements and tests for isolating transformers for the supply of medical locations (IEC 61558-2-15:2011); German version EN 61558-2-15:2012

German title
Sicherheit von Transformatoren, Drosseln, Netzgeräten und entsprechenden Kombinationen - Teil 2-15: Besondere Anforderungen und Prüfungen an Trenntransformatoren zur Versorgung medizinischer Räume (IEC 61558-2-15:2011); Deutsche Fassung EN 61558-2-15:2012
Publication date
2012-09
Original language
German
Pages
24

Please select

59.63 EUR VAT included

55.73 EUR VAT excluded

Purchasing options

Shipment (3-5 working days)
  • 59.63 EUR

Standards Ticker 1
1

Learn more about the standards ticker

Publication date
2012-09
Original language
German
Pages
24

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This part of IEC 61558 deals with safety aspects of isolating transformers for the supply of medical locations. Unless otherwise specified, the term transformer covers isolating transformers for the supply of medical locations. This Part 2-15 of IEC 61558 is applicable to stationary, single-phase or three-phase, air-cooled (natural or forced) independent dry-type isolating transformers for the supply of medical IT systems for group 2 medical locations, designed to be permanently connected to the fixed wiring and intended to form the IT power system on the secondary side. The windings may be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 000 V a.c. The rated supply frequency and internal operational frequency do not exceed 500 Hz. The rated output does not be less than 0,5 kVA and does not exceed 10 kVA for single-phase and three-phase transformers. This Part 2-15 of IEC 61558 is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. The no-load output voltage and the rated output voltage do not exceed 250 V a.c. for single-phase or three-phase transformer (phase-to-phase voltage). This standard does not cover power supply units. This part is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the appliance specification. The responsible committee is K 323 "Transformatoren, Drosseln, Netzgeräte und entsprechende Kombinationen" ("Transformers, reactors, power supply units and corresponding combinations thereof") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Replacement amendments

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...