Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories (IEC 60601-2-2:2017 + AMD1:2023); German version EN IEC 60601-2-2:2018 + A1:2024

Standard [CURRENT]

DIN EN IEC 60601-2-2:2025-06

VDE 0750-2-2:2025-06

Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories (IEC 60601-2-2:2017 + AMD1:2023); German version EN IEC 60601-2-2:2018 + A1:2024

German title
Medizinische elektrische Geräte - Teil 2-2: Besondere Festlegungen für die Sicherheit einschließlich der wesentlichen Leistungsmerkmale von Hochfrequenz-Chirurgiegeräten und Hochfrequenz-Chirurgischem Zubehör (IEC 60601-2-2:2017 + AMD1:2023); Deutsche Fassung EN IEC 60601-2-2:2018 + A1:2024
Publication date
2025-06
Original language
German
Pages
113

189.05 EUR VAT included

176.68 EUR VAT excluded

Format and language options

Shipment (3-5 working days)
  • 189.05 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2025-06
Original language
German
Pages
113
Loading recommended items...

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This standard specifies particular requirements for BASIC SAFETY and ESSENTIAL PERFORMANCE of HIGH FREQUENCY SURGICAL EQUIPMENT and HIGH FREQUENCY SURGICAL ACCESSORIES as defined in 201.3.224 and 201.3.223. The minimum safety requirements described in these Particular Requirements are intended to provide a reasonable degree of safety during the operation of HIGH FREQUENCY SURGICAL EQUIPMENT. These Particular Requirements extend and supplement IEC 60601-1:2005 and its Amendment 1:2012, Medical electrical equipment - Part 1: General requirements for basic safety and essential performance. The requirements are followed by specifications for the corresponding tests. HIGH FREQUENCY SURGICAL EQUIPMENT with a RATED OUTPUT POWER of not more than 50 W (for example for micro-coagulation, or for use in dentistry or ophthalmology) are exempt from certain of the requirements of this particular standard. These exemptions are indicated in the relevant requirements. The standard differs from DIN EN IEC 60601-2-2 (VDE 0750-2-2):2018-12 as follows: a) improvement and supplementation of the definitions of terms; b) additional separation of the requirements for HF surgical equipment and HF surgical accessories; c) new requirement that the contact quality of neutral electrodes used on adults shall be monitored; d) new requirements for equipment capable of high current operation or make use of such.

Replacement amendments

Cooperation at DIN

Loading recommended items...