Controlgear for electric light sources - Safety - Part 2-10: Particular requirements - Electronic controlgear for high-frequency operation of tubular cold-cathode discharge lamps (neon tubes) (IEC 61347-2-10:2024); German version EN IEC 61347-2-10:2024

Standard [PRE-ORDER]

DIN EN IEC 61347-2-10:2026-02

VDE 0712-40:2026-02

Controlgear for electric light sources - Safety - Part 2-10: Particular requirements - Electronic controlgear for high-frequency operation of tubular cold-cathode discharge lamps (neon tubes) (IEC 61347-2-10:2024); German version EN IEC 61347-2-10:2024

German title
Betriebsgeräte für elektrische Lichtquellen - Sicherheit - Teil 2-10: Besondere Anforderungen - Elektronische Wechselrichter und Konverter für Hochfrequenzbetrieb von röhrenförmigen Kaltstart-Entladungslampen (Neonröhren) (IEC 61347-2-10:2024); Deutsche Fassung EN IEC 61347-2-10:2024
Publication date
2026-02
Accessibility
Original language
German
Pages
24

64.40 EUR VAT included

60.19 EUR VAT excluded

Format and language options

Shipment (3-5 working days)
  • 64.40 EUR

Monitor with the Standards Ticker

This option is only available after login.
1

preorderable

Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2026-02
Original language
German
Pages
24
Loading recommended items...

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This document specifies safety requirements for electronic controlgear for high-frequency operation of tubular cold-cathode discharge lamps used in signs and luminous discharge tube installations and operating with an output voltage exceeding 1 000 V but not exceeding 10 000 V for direct connection to DC or AC supply voltages not exceeding 1 000 V (at 50 Hz or 60 Hz in case of alternating current). This document applies to controlgear types A and B that are specified as follows: -type A: controlgear operating within the frequency range of 20 kHz to 50 kHz having a maximum output peak voltage between terminals of 5 000 V and whose maximum output current is limited to 35 mA (rms) and 50 mA (peak value). The supply voltage does not exceed 250 V; - type B: controlgear that operates within the frequency range of 10 kHz to 100 kHz with a no-load output voltage between terminals of no more than 10 000 V and to earth of no more than 5 000 V and whose maximum output current is limited to 200 mA (rms) and 400 mA (peak value). This document contains no restrictions on the scope of application. The standard differs from DIN EN 61347-2-10 (VDE 0712-40):2009-06 and DIN EN 61347-2-10 Corrigendum 1 (VDE 0712-40 Corrigendum 1):2011-04 as follows: a) introduction of dated references as appropriate; b) clarification of sample item numbers. Typical examples of applications covered by this document include electronic inverters and converters for high-frequency operation of tubular cold-cathode discharge lamps (neon tubes) used, for example, in lighting installations for advertising signs and lighting installations for advertising devices.