Short-circuit currents in three-phase AC systems - Part 4: Examples for the calculation of short-circuit currents (IEC TR 60909-4:2021)

Technical rule [CURRENT]

DIN IEC/TR 60909-4:2024-12

VDE 0102-4:2024-12

Short-circuit currents in three-phase AC systems - Part 4: Examples for the calculation of short-circuit currents (IEC TR 60909-4:2021)

German title
Kurzschlussströme in Drehstromnetzen - Teil 4: Beispiele für die Berechnung von Kurzschlussströmen (IEC TR 60909-4:2021)
Publication date
2024-12
Original language
German
Pages
76

138.48 EUR VAT included

129.42 EUR VAT excluded

Format and language options

Shipment (3-5 working days)
  • 138.48 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2024-12
Original language
German
Pages
76

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This part of IEC 60909, which is a Technical Report, is intended to give help for the application of IEC 60909-0 for the calculation of short-circuit currents in 50 Hz or 60 Hz three-phase AC systems. This document does not include additional requirements but gives support for the modelling of electrical equipment in the positive-sequence, the negative-sequence and the zero-sequence system (Clause 4), the practical execution of calculations in a low-voltage system (Clause 5),a medium-voltage system with asynchronous motors (Clause 6) and a power station unit with its auxiliary network feeding a large number of medium-voltage asynchronous motors and low-voltage motor groups (Clause 7). The three examples given in Clauses 5, 6 and 7 are similar to those given in IEC TR 60909-4:2000 but they are revised in accordance with IEC 60909-0, which replaces it. The example given in Clause 8 is new and mirrors the introduction of the new 6.8 of IEC 60909-0:2016. Clause 9 gives the circuit diagram and the data of a test network and the results for a calculation carried out in accordance with IEC 60909-0, to offer the possibility for a comparison between the results found with a digital program for the calculation of short-circuit currents and the given results for I"k, ip, Ib, Ik, I"k1 and ip1 in a high-voltage network with power station units, generators, asynchronous motors and lines in four different voltage levels 380 kV, 110 kV, 30 kV and 10 kV. The standard differs from DIN EN 60909-0 Supplement 1 (VDE 0102 Supplement 1):2002-11 as follows: a) adaption to IEC 60909-0:2016; b) addition of an example for the calculation of short-circuit currents of wind power station units; c) correction of errors.