Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis (IEC 60601-2-33:2022 + ISH1:2023); German version EN IEC 60601-2-33:2024

Standard [CURRENT]

DIN EN IEC 60601-2-33:2025-07

VDE 0750-2-33:2025-07

Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis (IEC 60601-2-33:2022 + ISH1:2023); German version EN IEC 60601-2-33:2024

German title
Medizinische elektrische Geräte - Teil 2-33: Besondere Festlegungen für die Sicherheit von Magnetresonanzgeräten für die medizinische Diagnostik (IEC 60601-2-33:2022 + ISH1:2023); Deutsche Fassung EN IEC 60601-2-33:2024
Publication date
2025-07
Original language
German
Pages
168

233.18 EUR VAT included

217.93 EUR VAT excluded

Format and language options

Shipment (3-5 working days)
  • 233.18 EUR

Monitor with the Standards Ticker

This option is only available after login.
Easily subscribe: Save time and money now!

You can also subscribe to this document - together with other important standards in your industry. This makes your work easier and pays for itself after a short time.

Sparschwein_data
Subscription advantages
Sparschwein Vorteil 1_data

Important standards for your industry, regularly updated

Sparschwein Vorteil 2_data

Much cheaper than buying individually

Sparschwein Vorteil 3_data

Useful functions: Filters, version comparison and more

Publication date
2025-07
Original language
German
Pages
168
Loading recommended items...

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

This International Standard covers technical aspects of medical diagnostic MR systems and the MR equipment that are necessary to ensure patient safety and to address the problems of MR operators involved in the operation, development, manufacture, installation, and maintenance of MR systems with regard to exposure to electromagnetic fields (EMF). The exposure limits for patients and MR operators are selected to protect these individuals from adverse health effects and unreasonable risks. This document assumes that MR operators are monitored in accordance with occupational safety and health requirements and are trained and instructed in accordance with their specific duties. The standard differs from DIN EN 60601-2-33 (VDE 0750-2-33):2017-11 as follows: a) alignment with IEC 60601-1:2005 and its two amendments, IEC 60601-1:2005/AMD1:2012 and IEC 60601-1:2005/AMD2:2020; b) addition of safety requirements for the magnetic emergency shutdown unit; c)explanation of noise protection measures for the patient and the MR operator; d) addition of noise emission specifications for exposure within the MR examination room in order to support the occupational health assessment by the responsible organization; e) addition of procedures with regard to compliance with thermal safety requirements for RF coils; f) specifications for RF excitation to align with the labeling requirements for conditionally MR safe medical devices; g) explanation of the requirements for labeling accessories as conditionally MR safe; h) adjustment of the static magnetic field limit value for the B0 hazard zone to align with the limit values in other standards for medical devices (in particular pacemakers, ISO 14117), resulting in a new limit value of 0,9 mT; i) improved description of the magnetic field-related diagrams in the Compatibility Technical Specification Sheet (CTSS); j) the requirement for compatibility sequences (in the CTSS) for testing accessories by the MR manufacturer has been made optional, and it is expected to be removed in one of the next editions; k) a separate subclause with requirements for site planning documents containing safety information; l) requirements for the alarm (notification) function (patient to operator); m) introduction of MROC as a mandatory function for 1,5-T and 3-T systems in order to support the examination of patients with medical devices labeled as conditionally MR safe, provided that such imaging is not expressly contraindicated by the MR manufacturer; n) the symbols for RF coils in Table 201.A.102 have become mandatory, and the preferred and alternative symbols have been exchanged compared to the previous edition, so that the colored symbol is now preferred; o) determination of the B1 stray field in 201.12.4.105.3.3 based exclusively on calculations.

Cooperation at DIN

Loading recommended items...