To our valued customers,

At last: 

Beuth Verlag is now DIN Media. 

You can find out more about our new name and the reasons behind it here.

To use our new website without any hiccups, please clear your browser cache. 

Yours sincerely,

DIN Media

Standards Worldwide
Standards Worldwide
Phone +49 30 58885700-07

Draft pre-standard [WITHDRAWN]

DIN VDE V 0210-9:2017-04 - Draft

VDE V 0210-9:2017-04

Overhead electrical lines exceeding 45 kV - Hybrid AC/DC transmission and DC transmission

German title
Freileitungen über 45 kV - Hybride AC/DC-Übertragung und DC-Übertragung
Date of issue
2017-03-17
Publication date
2017-04
Original language
German
Pages
43
Procedure
Pre-Standard

Please select

41.72 EUR VAT included

38.99 EUR VAT excluded

Purchasing options

Shipment (3-5 working days) 1
  • 41.72 EUR

1

 Attention: Document withdrawn!

Date of issue
2017-03-17
Publication date
2017-04
Original language
German
Pages
43
Procedure
Pre-Standard

Quick delivery via download or delivery service

Buy securely with a credit card or pay upon receipt of invoice

All transactions are encrypted

Overview

The transmission capacity of existing overhead lines can be increased, for example, by using different cables, weather-dependent operation of the overhead line or conversion from alternating current (AC) to direct current (DC). While use of the first two options has already been described in standards or application rules, the third option has not yet been addressed. The conversion of an existing circuit from AC to DC on an existing pylon that also carries other AC circuits (AC/DC overhead line) or the construction of a parallel DC overhead line requires additions or the revision of the previous design criteria DIN EN 50341 (VDE 0210). This pre-standard focuses on the electrical requirements (insulation coordination, clearances, earthing, etcetera) and the requirements for overhead line insulators and fittings for AC/DC or DC overhead lines. This prestandard applies for the planning and installation of high-voltage overhead electrical lines with hybrid AC/DC systems, one or more AC circuits are in parallel with one or more DC circuits in close vicinity. It also applies for the planning and installation of DC high-voltage overhead electrical lines. In this prestandard AC systems with a nominal voltage exceeding 45 kV and DC systems with a rated voltage exceeding 45 kV are regarded as high-voltage overhead electrical lines. The responsible committee is DKE/K 421 "Freileitungen" ("Overhead lines") of the DKE (German Commission for Electrical, Electronic and Information Technologies) at DIN and VDE.

Replacement amendments

This document has been replaced by: DIN VDE V 0210-9:2018-03; VDE V 0210-9:2018-03 .

Cooperation at DIN

Loading recommended items...
Loading recommended items...
Loading recommended items...
Loading recommended items...